HP Integrity rx7620 Server - User Service Guide, Sixth Edition

Updating Option ROMs
The Option ROM on a PCI I/O card can be “flashed” or updated. To flash an I/O card, follow
these steps:
1. Install the I/O card into the chassis.
2. Boot the server to the EFI shell.
3. Run the EFI search command.
To add a single card:
search <cell> <pci_slot #>
To add all cards:
search all
4. Run the EFI map r command:
NOTE: Each I/O card type and firmware image update may require a different flash utility
and procedure. Follow the instructions in the .txt file included with the latest HP IPF
Offline Diagnostic & Utilities CD.
5. Load the HP IPF Offline Diagnostic & Utilities CD.
The CD contains the flash utility for IO for each card type, firmware images, and a .txt
file that includes instructions and information about updating the firmware images.
Removing and Replacing the PCI-X Card Cage Assembly
The PCI-X card cage comes with the PCI-X backplane located in the rear of the server. All system
power must be removed before attempting to remove or replace this component. For more
information, see “Shutting Down nPartitions and Powering Off Hardware Components
(page 96).
CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to
follow ESD safety precautions can result in damage to the server.
Figure 6-27 PCI-X Card Cage Assembly Location
Removing and Replacing the PCI-X Card Cage Assembly 121