HP Integrity rx7620 Server - User Service Guide, Sixth Edition

Firmware updating progress is reported) NOTE (1): When a SEU is connected to an system,
cabinet id 8 is assigned to the SEU. NOTE (2): These entities might be different depending
on your server. NOTE (3): X.X.X is the version number corresponding to the version of the
FPGA on the other cells.
CAUTION: DO NOT RESET the cell or server unless you have received confirmation that
the FPGAs were updated successfully. Repeat the firmware update procedure immediately
for all entities failing to update successfully.
2. Verify that you have received confirmation that the FPGA was updated successfully. If any
entity failed to update properly do not continue until the entity have been successfully
updated. A successful update returns the following message:
OSP has completed successfully for all selected FPGAs.
NOTE: FPGAs updated in step 4 will not show the updated version when running the
sysrev command until after the next AC cycle of the cell. Once ALL firmware images have
been updated, you are instructed to AC cycle the cell later in this procedure.
3. Do not reset the cell until the next step (step 4) is completed.
4. Run the Firmware Update Utility to update Cell PDHC version (s) to A.X.X.X (See Note
(1) in this step) using the fw command:
MP:CM> fw
Enter the following information when prompted:
Enter the Entities to be upgraded (Ex: 3,4,10): (1)
Enter your user name: (2)
Enter your user password: (3)
Enter the ip address where the firmware can be found: (4)
Enter the path where the firmware can be found: (5)
Enter the filename of the firmware image for the PDHC: (6)
Enter the filename of the System Firmware image: (7)
Enter the filename of the firmware image for the MP: (8)
Are you sure that you want to continue (Y/N): y
(1) Select the appropriate entity corresponding to the replacement cell to be upgraded /
downgraded by entering the number from the first column of the FW table.(2) Enter your
user name. (3) Enter account password. (4) Enter the ip address of the anonymous FTP server
where the firmware images reside. (5) Enter the directory path. For example:
/dist/versionX_X (or some other location). Do not list the actual firmware image filename.
(6) Enter the PDHC filename: pdhc_A.X.X.X.bin (See Note (1) in this step). NOTE (1):
X.X.X is the version number corresponding to the version of the PDHC firmware on the
other cells.
Example:
MP:CM> fw
*********************************************************************
***** *****
***** Firmware Update Utility *****
***** *****
***** (C) Copyright 2001 Hewlett-Packard Company *****
***** All Rights Reserved *****
***** *****
***** THIS PROGRAM IS NOT LICENSED TO CUSTOMERS *****
***** *****
***** This program is intended for use by trained HP support *****
***** personnel only. HP shall not be liable for any damages *****
***** resulting from unauthorized use of this program. This *****
***** program is the property of HP. *****
***** *****
***** Version 4.00 *****
134 Removing and Replacing Components