HP Integrity rx7620 Server - User Service Guide, Sixth Edition
***** *****
*********************************************************************
Flash Current
Number Cabinet Name Partition Handle Firmware Version Comments
------ --------- -------- ---------- -------- ------------------ --------
(1) 1 0 MP 0 0 0 5.022 Master
(1) 2 0 MP 1 1 1 5.022 Slave
(3) 3 (2) 8 MP 0 0 32768 5.022 Master
(3) 4 (2) 8 MP 1 1 32769 5.022 Slave
5 0 PDHC 0 0 256 3.012 -
6 0 SFW 0 0 320 21.003 -
7 0 PDHC 1 1 257 3.014 -
8 0 SFW 1 1 321 21.003 -
(3) 9 0 PDHC 2 0 258 3.014 -
(3) 10 0 SFW 2 0 322 21.003 -
(3) 11 0 PDHC 3 1 259 3.014 -
(3) 12 0 SFW 3 1 323 21.003 -
Enter the Entities to be upgraded (Ex: 3,4,10): 5
Enter your user name: anonymousEnter your user password: ********
Enter the ip address where the firmware can be found: 192.1.1.1
Enter the path where the firmware can be found: /dist/versionX_X
Enter the filename of the firmware image for the PDHC: pdhc_A.X.X.X.bin
Are you sure that you want to continue(Y/N): y
**** Firmware Updating PDHC ****
(Firmware updating progress is reported) NOTE (1): Cabinet id 8 is assigned to the SEU.
NOTE (2): These entities might be different depending on your server. NOTE (3): X.X.X is
the version number corresponding to the version of the PDHC Firmware on the other cells.
5. Ensure the entity selected was updated successfully. A successful update returns the following
message:
Firmware Update has completed successfully for all entities.
MP:CM>
An unsuccessful update results in an error message. If the FTP connection was successful,
but the update failed, a warning is noted for the entity being updated. For example:
Firmware Update failed for entity SFW 0.
DO NOT REBOOT SFW 0 until it has been successfully updated!!!
Firmware Update completed with errors.
CAUTION: Repeat the firmware update procedure immediately for all entities failing to
update successfully. DO NOT RESET or AC POWER CYCLE until you get a message
indicating that all updates have completed successfully.
6. Activate the new Firmware for all updated components by cycling power to the cell, following
these specific steps:
a. Eject the Cell.
b. Reinsert the Cell.
7. Following the Cell AC power cycle, verify the updated firmware revisions by using the
sysrev command.
Example:
MP:CM> sysrev
Cabinet firmware revision report
PROGRAMMABLE HARDWARE :
System Backplane : GPM FM OSP
------- ------- -------
1.002 1.002 1.002
PCI-X Backplane : LPM HS
------- -------
2.000 1.000
Removing and Replacing a Cell Board 135