HP Integrity rx7620 Server - User Service Guide, Sixth Edition
Core IO : Master Slave
-------- -------
2.009 2.009
LPM PDHC
------- -------
Cell 0 : 1.002 1.007
Cell 1 : 1.002 1.007
Cell 2 : 1.002 1.007
Cell 3 : 1.002 1.007
FIRMWARE:
Core IO
Master : A.006.012
Event Dict. : 0.009
Slave : A.006.012
Event Dict. : 0.009
Cell 0
PDHC : A.003.023
Pri SFW : 21.003 (PA)
Sec SFW : 21.003 (PA)
Cell 1
PDHC : A.003.023
Pri SFW : 21.003 (PA)
Sec SFW : 22.002 (PA)
Cell 2
PDHC : A.003.023
Pri SFW : 21.003 (PA)
Sec SFW : 22.002 (PA)
Cell 3
PDHC : A.003.023
Pri SFW : 21.003 (PA)
Sec SFW : 22.002 (PA)
IO Cabinet FPGA and Firmware revision report
System Backplane : GPM FM OSP
------- ------- -------
1.002 1.002 1.002
PCI-X Backplane : LPM HS
------- -------
2.000 1.000
FPGA MP
------- -------
IOX Master Core IO : 2.009 A.006.012
Event Dict. 0.009
IOX Slave Core IO : 2.009 A.006.012
Event Dict. 0.009
NOTE: System Firmware does not display the correct revision until it has been updated
separately in step 8.
8. Having verified that all other firmware components have been updated successfully, run
the Firmware Update Utility to update Cell System Firmware version(s) to A.X.X.X (See
Note (1) in this step) using the fw command:
MP:CM> fw
Enter the following information when prompted:
Enter the Entities to be upgraded (Ex: 3,4,10): (1)
Enter your user name: (2)
Enter your user password: (3)
Enter the ip address where the firmware can be found: (4)
136 Removing and Replacing Components