HP Integrity rx7620 Server - User Service Guide, Sixth Edition
Enter the path where the firmware can be found: (5)
Enter the filename of the firmware image for the PDHC: (6)(a or b)
Enter the filename of the System Firmware image: (7)
Enter the filename of the firmware image for the MP: (8)
Are you sure that you want to continue (Y/N): y
(1) Select the appropriate entity corresponding to the replacement cell to be upgraded /
downgraded by entering the number from the first column of the FW table(2) Enter your
user name.(3) Enter account password.(4) Enter the IP address of the anonymous FTP server
where the firmware images reside.(5) Enter the directory path. For example:
/dist/versionX_X (or some other location). Do not list the actual firmware image filename.
(6a) Enter the System Firmware filename: pinn.bin.X.X.fh (See Note (1) in this step).
(6b) Enter the System Firmware filename: sfw.X.X.X.fh (See Note (1) in this step). NOTE
(1): X.X.X is the version number corresponding to the version of the System firmware on
the other cells.
Example:
MP:CM> fw
*********************************************************************
***** *****
***** Firmware Update Utility *****
***** *****
***** (C) Copyright 2001 Hewlett-Packard Company *****
***** All Rights Reserved *****
***** *****
***** THIS PROGRAM IS NOT LICENSED TO CUSTOMERS *****
***** *****
***** This program is intended for use by trained HP support *****
***** personnel only. HP shall not be liable for any damages *****
***** resulting from unauthorized use of this program. This *****
***** program is the property of HP. *****
***** *****
***** Version 4.00 *****
***** *****
*********************************************************************
Flash Current
Number Cabinet Name Partition Handle Firmware Version Comments
------ --------- -------- ---------- -------- ------------------ --------
(1) 1 0 MP 0 0 0 5.022 Master
(1) 2 0 MP 1 1 1 5.022 Slave
(3) 3 (2) 8 MP 0 0 32768 5.022 Master
(3) 4 (2) 8 MP 1 1 32769 5.022 Slave
5 0 PDHC 0 0 256 3.014 -
6 0 SFW 0 0 320 21.001 -
7 0 PDHC 1 1 257 3.014 -
8 0 SFW 1 1 321 22.002 -
(3) 9 0 PDHC 2 0 258 3.014 -
(3) 10 0 SFW 2 0 322 22.002 -
(3) 11 0 PDHC 3 1 259 3.014 -
(3) 12 0 SFW 3 1 323 22.002 -
Enter the Entities to be upgraded (Ex: 3,4,10): 6
Enter your user name: anonymousEnter your user password: ********
Enter the ip address where the firmware can be found: 192.1.1.1
Enter the path where the firmware can be found: /dist/versionX_X
Enter the filename of the System Firmware image: pin.bin.X.X.fh
Are you sure that you want to continue(Y/N): y
**** Firmware Updating System Firmware ****
(Firmware updating progress is reported) NOTE (1): Cabinet id 8 is assigned to the SEU.
NOTE (2): These entities might be different depending on your server. NOTE (3): X.X.X is
the version number corresponding to the version of the System Firmware on the other cells.
9. Ensure the entity selected was updated successfully. A successful update returns the following
message:
Firmware Update has completed successfully for all entities.
Removing and Replacing a Cell Board 137