HP Integrity rx7620 Server - User Service Guide, Sixth Edition

MP:CM>
An unsuccessful update results in an error message. If the FTP connection was successful,
but the update failed, a warning is noted for the entity being updated. For example:
Firmware Update failed for entity SFW 0.DO NOT REBOOT SFW 0 until
it has been successfully updated!!!Firmware Update completed with
errors.
CAUTION: Repeat the firmware update procedure immediately for all entities failing to
update successfully. DO NOT RESET or AC POWER CYCLE until you get a message
indicating that all updates have completed successfully.
10. Verify the updated firmware revisions using the sysrev command. Example:
MP:CM> sysrev
Cabinet firmware revision report
PROGRAMMABLE HARDWARE :
System Backplane : GPM FM OSP
------- ------- -------
1.002 1.002 1.002
PCI-X Backplane : LPM HS
------- -------
2.000 1.000
Core IO
: Master Slave
-------- -------
2.009 2.009
LPM PDHC
------- -------
Cell 0 : 1.002 1.007
Cell 1 : 1.002 1.007
Cell 2 : 1.002 1.007
Cell 3 : 1.002 1.007
FIRMWARE:
Core IO
Master : A.006.012
Event Dict. : 0.009
Slave : A.006.012
Event Dict. : 0.009
Cell 0
PDHC : A.003.023
Pri SFW : 21.003 (PA)
Sec SFW : 22.002 (PA)
Cell 1
PDHC : A.003.023
Pri SFW : 21.003 (PA)
Sec SFW : 22.002 (PA)
Cell 2
PDHC : A.003.023
Pri SFW : 21.003 (PA)
Sec SFW : 22.002 (PA)
Cell 3
PDHC : A.003.023
Pri SFW : 21.003 (PA
Sec SFW : 22.002 (PA)
IO Cabinet FPGA and Firmware revision report
System Backplane : GPM FM OSP
------- ------- -------
1.002 1.002 1.002
PCI-X Backplane : LPM HS
------- -------
2.000 1.000
138 Removing and Replacing Components