HP Integrity rx7620 Server - User Service Guide, Sixth Edition
Figure 3-8 PCI I/O Slot Details
7. Wait for the green power LED to stop blinking.
8. Check for errors in the hotplug daemon log file (default: /var/adm/hotplugd.log).
The critical resource analysis (CRA) performed while doing an attention button initiated
add action is very restrictive and the action will not complete–it will fail–to protect critical
resources from being impacted. For finer control over CRA actions, use pdweb or the olrad
command. For details, see the Interface Card OL* Support Guide located on the HP website at
http://docs.hp.com.
9. Replace the top cover.
10. Connect all cables to the installed PCI card.
DVD+RW Installation Instructions
The CD/DVD/DAT is located in the front of the chassis. You must remove the system power to
this component before attempting to remove or replace it. See “Shutting Down nPartitions and
Powering Off Hardware Components ” (page 96).
To install the DVD+RW drive, follow these steps:
CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to
follow ESD safety precautions can result in damage to the server.
1. Remove the front bezel and top cover. See “Removing and Replacing the Front Bezel”
(page 99) and see “Removing and Replacing the Top Cover” (page 99) .
2. Remove the drive bay blank or removable media drive.
50 Installing Additional Components