HP Integrity rx7620 Server - User Service Guide, Sixth Edition
Figure 4-11 Example sa Command
5. Launch a web browser on the same subnet using the IP address for the MP LAN port.
Figure 4-12 Browser Window
6. Click anywhere on the Zoom In/Out title bar to generate a full screen MP window.
7. Select the emulation type you want to use.
8. Log in to the MP when the login window appears.
Access to the MP using a web browser is now possible.
Verifying the Presence of the Cell Boards
To perform this activity, either connect to the MP using a console, or connect the CE Tool (laptop)
to the RS-232 local port on the MP.
After logging in to the MP, verify that the MP detects the presence of all the cells installed in the
cabinet. It is important for the MP to detect the cell boards. If it does not, the partitions do not
boot.
To determine if the MP detects the cell boards, follow these steps:
66 Cable Connections