HP Integrity rx7620 Server - User Service Guide, Sixth Edition

Table 5-2 Front Panel LEDs
DescriptionStateDriven ByLED
48V Good (LED works even if MP is not installed, or
installed and not active)
On GreenGPM
1
Power
48V OffOff
3.3V standby good (LED works even if MP is not installed,
or installed and is not active)
On GreenGPMStandby Power
3.3V OffOff
At least one MP is installed and activeOn GreenGPMMP
2
Present
No MPs are installed or at least one is installed but not
active
Off
Dial-in (remote) console enabledOn GreenMP thru GPMRemote
Dial-in (remote) console is disabled, or MP not installed,
or MP installed and not active
Off
Chassis log alert unreadFlash YellowMP thru GPMAttention
No alert, or MP not installed, or MP installed and not activeOff
One or more partitions runningOn GreenPDC
3
/MP thru
GPM
Run
No partition running, or MP not installed, or MP installed
and not active
Off
One or more partitions have reported a faultFlash RedPDC/MP thru
GPM
Fault
No partitions running, or MP not installed, or MP installed
and not active
Off
1 GPM stands for global power monitor
2 MP stands for manageability processor
3 PDC stands for processor dependent code
Bulk Power Supply LEDs
There is a single three-color LED on each bulk power supply.
76 Troubleshooting