HP Integrity rx7620 Server - User Service Guide, Sixth Edition
Figure 5-4 PCI-X Power Supply LED Locations
Table 5-4 PCI-X Power Supply LEDs
DescriptionStateDriven ByLED
All output voltages generated by the power supply are
within limits.
On GreenEach supplyPower
Power to entire system has been removed.Off
For LED status in combination with the green power LED
for PCI-X slot status, see Table 5-9.
YellowMP through PCI
LPM
1
Attention
The temperature within the power supply is above the
lower threshold.
Flash YellowEach supplyFault
The temperature of the power supply is approaching the
thermal limit.
On Yellow
Power supply has shut down due to an over temperature
condition, a failure to regulate the power within expected
limits, or a current-limit condition.
Flash Red
Normal operation.Off
1 LPM stands for local power monitor
System and PCI I/O Fan LEDs
There is a single three-color LED on each system and PCI I/O fan.
78 Troubleshooting