SmartSetup Scripting Toolkit Deployment Guide for HP Integrity Servers with Windows Server 2003 and Windows Server 2008 for Itanium-based Systems

1. Connect to the target server through either telnet or SSH in order to access the MP. At any
time, type Ctrl+B to return to the MP.
2. Enter the command menu as follows:
servernameMP> CM
3. Reset the system. Enter:
servernameMP> RS
Troubleshooting
Preventing error 0x07B during installation (Windows Server 2003 Enterprise only)
To prevent the error 0x07B from occurring during installation, follow these steps:
1. Ensure that the target controller is supported by Windows 2003 Enterprise (see Appendix A
(page 71)). If not, set the controller variable that specifies the controller model (see “Editing
the SSTKConfig.cmd file” (page 30)).
2. Ensure that the OEM driver for this controller is present in the repository (see “Uploading
OEM device drivers” (page 28)).
3. Ensure that the disk ID configured in the diskpart script corresponds to a disk connected
to that controller.
Troubleshooting 35