SmartSetup Scripting Toolkit Deployment Guide for HP Integrity Servers with Windows Server 2003 and Windows Server 2008 for Itanium-based Systems

Table 6-2 hpacubin Error Codes (continued)
ReasonErrorCode
The specified Expand Priority is not supported. Also, this error
occurs if the controller does not allow expansion and therefore
does not support Expand Priority.
Invalid Expand Priority
2824
The Array ID is invalid.
Invalid Array
2825
The array command is missing from the script file. Some
commands were found that require an array to work on.
Array not specified
2826
The Array ID in the script file does not match the Array ID of
the newly created array. For example, if you have Array A
already and the script file tries to create Array C (without Array
B), the script generates this error.
New Array ID does not match
the next available Array ID
2827
When running in Configure mode, this error happens when the
Array ID in the script file already exists in the configuration.
Configure mode can only create new arrays.
New Array ID already exists
2828
The controller does not allow a new array to be created. Possible
causes are there are no unassigned physical drives on the
controller or the maximum number of arrays or logical drives
has already been reached.
Cannot create Array
2829
The array cannot be expanded. Possible causes are the controller
does not support expansion or the current configuration does
not allow expansion to occur on the array.
Cannot expand Array
2830
The spare state of the array cannot be changed. This can happen
when adding a spare or dropping a spare. The current
configuration does not allow a spare state change for the array.
Cannot change Array Spare
2831
The physical drive listed for the array is not a valid physical
drive, or it is a physical drive that is not capable of being placed
in the array.
Invalid Physical Drive
2832
The spare drive listed for the array is not a valid spare drive, or
it is a drive that is not capable of being placed on the array as a
spare.
Invalid Spare
2833
The Logical Drive ID is not valid.
Invalid Logical Drive
2834
The Logical Drive command is missing from the script file. Some
commands were found that require a Logical Drive to work on.
Logical Drive not specified
2835
The Logical Drive ID in the script file does not match the Logical
Drive ID of the newly created logical drive. For example, if you
already have Logical Drive 1 and the script file attempts to create
Logical Drive 3 (without Logical Drive 2), the script generates
this error. This error can occur when using an input file with
logical drive numbers that are not sequential. In this case, you
must change the logical drive numbers so that they are sequential
in the input file.
New Logical Drive ID does
not match the next available
Logical Drive ID
2836
When running in Configure mode, this error occurs when the
Logical Drive ID in the script file already exists in the
configuration. Configure mode can only create new logical drives.
New Logical Drive ID already
exists
2837
The controller does not allow a new logical drive to be created.
Possible causes are there is no free space on the array or the
maximum number of logical drives has already been reached.
Cannot create Logical Drive
2838
The controller does not support migration, or the current
configuration of the controller does not allow migration to occur.
Cannot migrate Logical Drive
Raid
2839
The controller does not support migration, or the current
configuration of the controller does not allow migration to occur.
Cannot migrate Logical Drive
Stripe Size
2840
50 Utilities reference