SmartSetup Scripting Toolkit Deployment Guide for HP Integrity Servers with Windows Server 2003 and Windows Server 2008 for Itanium-based Systems

Table 6-2 hpacubin Error Codes (continued)
ReasonErrorCode
The controller does not support extension, or the current
configuration of the controller does not allow extension to occur.
For example, there might be no free space on an array, so
extension is not supported for the logical drive.
Cannot extend Logical Drive
2841
The specified RAID is invalid or is not possible with the current
configuration.
Invalid Raid
2842
The specified size is invalid or is not possible with the current
configuration.
Invalid Size
2843
The specified stripe size is invalid, is not supported with the
current RAID level, or is not supported with the current
configuration.
Invalid Stripe Size
2844
The specified Max Boot setting is invalid, or is not supported
with the current configuration.
Invalid Sectors
2845
You cannot change the Max Boot setting on a configured logical
drive. This leads to data loss.
Cannot change Logical Drive
Sectors
2846
The specified Array Accelerator setting is invalid or is not
supported with the current configuration.
Invalid Array Accelerator
Setting
2847
The current controller configuration does not support changing
the logical drive Array Accelerator state.
Cannot change Logical Drive
Array Accelerator Setting
2848
The specified ClearConfigurationWithDataLoss parameter is not
correct.
Invalid
ClearConfigurationWithDataLoss
parameter
2849
The controller does not support Raid Array ID.
Controller does not support
Raid Array ID
2850
The entered Raid Array ID is invalid. The Raid Array ID can
only consist of the following characters: a-z, A-Z, 0-9, ! @ # * ( ) ,
- _ + : . / [space]. It cannot end with a space character or exceed
the maximum number of characters allowed by the controller.
Invalid Raid Array ID
2851
The requested SSP State is not a valid SSP state.
Invalid SSP State
2852
The SSP settings cannot be changed for the controller or logical
drive.
Cannot change SSP settings
2853
The adapter ID is not a valid adapter ID that was detected by
the controller.
Invalid SSP Adapter ID
2854
The Controller does not support Logical Drive SSP states. Use
the SSPState controller command to set the Controller SSP
state.
Controller does not support
Logical Drive SSP states.
Use 'SSPState' Controller
command to set the
Controller SSP state
2855
Controller does not support Controller SSP state. Use
LogicalDriveSSPState logical drive command to set SSP
states for each Logical Drive.
Controller does not support
Controller SSP state. Use
'LogicalDriveSSPState'
Logical Drive command to set
SSP states for each Logical
Drive
2856
Invalid Surface Scan Delay
Invalid Surface Scan Delay
2857
The controller does not support the snapshot resource volume
feature.
Controller does not support
snapshot resource volume
feature
2858
hpacubin 51