HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
Power supply failure. Probable Cause: The system has detected that one of the power
supplies has failed. Recommended Action: The power cable has been disconnected.
Reconnect, or The power supply has failed. Contact your HP support representative
to check the power supply. WBEM EventID: 137. WBEM ProviderName:
SEL02_IndicationProvider.Warning720
Power supply AC lost. Probable Cause: The power supply has lost its A/C source.
The power supply is not connected to a working A/C power source. Recommended
Action: Verify that the plug is connected to the power supply, and to a working
power source. WBEM EventID: 139. WBEM ProviderName: SEL02_IndicationProvider.Warning722
Power failure in power supply. Probable Cause: Indicates a failure with the AC power
source that is connected to one of the redundant power supply units. Recommended
Action: Check the power cord or source voltage. WBEM EventID: 155. WBEM
ProviderName: SEL02_IndicationProvider.Error726
Voltage reached critical level. Probable Cause: The voltage in the server has gone
outside the factory set range. A bad component, blown fuse, poorly seated module,
loose cable, or debris could be responsible for this failure. Recommended Action:
Check all boards, power supplies, and modules that either supply or use this voltage
rail. WBEM EventID: 119. WBEM ProviderName: SEL02_IndicationProvider.Error728
System shut-down or reset caused by sensor reading. Probable Cause: A sensor
reading in the system was determined to be non-recoverable and the system was
shut down or reset. Recommended Action: Read the system logs to find which sensor
was out of range. WBEM EventID: 167. WBEM ProviderName:
SEL02_IndicationProvider.Error729
The BMC firmware did not detect the system firmware boot. Probable Cause: Possible
Causes: 1. Bad System Firmware image in ROM 2. Power not reaching processors 3.
Processor is in reset or is not properly seated in system 4. An unsupported processor
was inserted in system 5. Communication with BMC is impaired. Recommended
Action: To correct the problem, try the following: 1. Validate that processors are
supported in this system. 2. Verify that processors are seated properly in system. 3.
Check if system has booted (only a communication problem. - future events will also
be lost.) 4. Attempt a system reset, INIT, and/or A/C cycle to clear the problem. 5.
Update system firmware again if necessary. WBEM EventID: 132. WBEM
ProviderName: SEL02_IndicationProvider.Error730
A/C Power failed, disconnected, or out of range. Probable Cause: The input power
to the supply has failed or gone out of range. Or the input cord has been disconnected.
Recommended Action: Check the power cord or source voltage. WBEM EventID:
154. WBEM ProviderName: SEL02_IndicationProvider.Error731
The power supply sensors detect a possible problem. Probable Cause: The power
supply fan(s) is slowing. Recommended Action: Check power supply fan(s). WBEM
EventID: 138. WBEM ProviderName: SEL02_IndicationProvider.Warning732
Cooling unit warning. Probable Cause: The Cooling Unit may be running properly
now, but it was detected in a degraded state. It may need to be replaced in the future.
Recommended Action: Continue to monitor unit and contact HP support to determine
appropriate action. WBEM EventID: 157. WBEM ProviderName:
SEL02_IndicationProvider.Warning733
Cooling unit failure. Probable Cause: A cooling unit has failed. Recommended Action:
Replace the indicated cooling unit. WBEM EventID: 158. WBEM ProviderName:
SEL02_IndicationProvider.Error734
BMC entering special mode. Probable Cause: BMC entering special mode. The system
is not operating in a normal configuration. Some protection features may be disabled
in this mode. Recommended Action: The Special Mode must be exited to ensure
proper operation of the server. WBEM EventID: 166. WBEM ProviderName:
SEL02_IndicationProvider.Warning735
10 WBEM Provider Event Tables