HP Insight Management WBEM Provider Events Reference Guide

Power not turned on. The iLO peer to peer LAN communication is not functional.
Probable Cause: The iLO peer to peer LAN communication is not fully functioning.
Could be caused by issues with the internal LAN or iLO code. Recommended Action:
Review the logs to determine details of failure. The management system will attempt
to repair itself. If the management system does not recover refer to the Service Guide
to determine how to reset iLO without a user interface. WBEM EventID: 9921. WBEM
ProviderName: FPL_IndicationProvider.Error14542
Virtual Connect failed to save FRU data into NVM. Probable Cause: An error occurred
in the interface between system firmware and manageability firmware while saving
persistent data. iLO may have been temporarily busy and may have missed an update.
Recommended Action: Reboot the server and verify that the system board or mezz
card containing this FRU is functioning properly. If not, replace the mezz card or
system board containing this FRU.Check system logs to see if other NVM errors are
related to this same board / card. If so, replace the board / card containing this
FRU.Verify system and manageability firmware are at their currently supported
revisions.If problems persist, contact Support. WBEM EventID: 9838. WBEM
ProviderName: FPL_IndicationProvider.Warning14546
The system will experience a hard reset as a result of a watchdog timeout. Probable
Cause: The OS Watchdog has timed out. Recommended Action: System will be reset.
Determine why the OS did not reset the watchdog. Consider changing the action to
'no action' for debug. Look for other unusual OS activity. WBEM EventID: 9922.
WBEM ProviderName: FPL_IndicationProvider.Error14552
The system will power down as a result of a watchdog timeout. Probable Cause: The
OS Watchdog has timed out. Recommended Action: Review logs and power system
back on if no concerning events are observed.Determine why OS failed to reset the
watchdog. Consider changing action to 'no action' for debug. Look for other unusual
OS activity. WBEM EventID: 9923. WBEM ProviderName: FPL_IndicationProvider.Error14553
The system will power cycle as a result of a watchdog timeout. Probable Cause: The
OS Watchdog has timed out. Recommended Action: None. System will power back
on in a moment. WBEM EventID: 9924. WBEM ProviderName:
FPL_IndicationProvider.Error14554
Unable to retrieve error information after a fatal error. Probable Cause: A fatal error
has occurred. In attempting to configure hardware for error information recovery
the valid signature wasnt found in the fatal error registers. Recommended Action:
Review logs for indicators of what might have happened, and monitor system health.
WBEM EventID: 9925. WBEM ProviderName: FPL_IndicationProvider.Error14559
Failed to initialize shared memory. Probable Cause: Either the hardware (RAM) did
not respond to the initialization requests, or there was a FW issue during setup of
the shared memory task. Recommended Action: Try resetting iLO with an xd->R
command from the iLO CM> prompt. WBEM EventID: 9926. WBEM ProviderName:
FPL_IndicationProvider.Error14560
The Display Board is not responding and may be missing. Probable Cause: The
Display Board is not responding. It is either missing or loose. This board includes
sensors such as the altimeter and a thermal sensor so operation may be altered.
Recommended Action: Check if the board is present. If not replace it. If it is, remove
it and re-insert it to ensure proper connectivity. WBEM EventID: 9927. WBEM
ProviderName: FPL_IndicationProvider.Error14564
integrated Lights Out firmware battery failure of NVRAM state change. Probable
Cause: Determine if the firmware was recently upgraded. This is often the reason
for the NVRAM to change. If not, and the A/C power has been removed, than it's
possible the battery is indeed going bad and would need to be replaced.
Recommended Action: If battery is suspected change the battery. WBEM EventID:
9899. WBEM ProviderName: FPL_IndicationProvider.Warning14578
integrated Light Out firmware software error. Probable Cause: A software error was
detected and is being logged. The internal data is connected to the location and
module where the error occurred. The Forward Progress Log may receive additional
(lower alert level) event entries with more data associated with this event.
Recommended Action: Review logs, and monitor system health. WBEM EventID:
9900. WBEM ProviderName: FPL_IndicationProvider.Warning14579
100 WBEM Provider Event Tables