iLO was unable to initialize user accounts. Probable Cause: iLO was unable to read
the default user account data from EEPROM. The default user data contained in the
EEPROM was likely bad, or the checksum failed. Recommended Action: There is no
factory default password at this point- all passwords will be refused. Use the physical
presence button to force iLO into security override mode. This will allow you to log
into iLO without a user account. Use the UC command or web GUI to setup iLO user
account(s) again. WBEM EventID: 10073. WBEM ProviderName:
FPL_IndicationProvider.Warning14690
SFW discarded one or more in progress SFW events before they got logged by iLO.
Probable Cause: The SFW event queue overflowed and remained that way for a
duration of time. This could result from poor iLO queue draining (logging)
performance, or could be related to the number of event being issued by SFW in a
short period of time. Recommended Action: None. WBEM EventID: 10166. WBEM
ProviderName: FPL_IndicationProvider.Warning14730
The iLO config was unexpectedly defaulted. Settings may need to be re-entered.
Probable Cause: Some bad data in the iLO config area of NVRAM was detected and
as a result config was defaulted. It is not believe that this was caused by a battery
failure or user action. Recommended Action: Re-enter any lost configuration data.
WBEM EventID: 10172. WBEM ProviderName: FPL_IndicationProvider.Warning14744
The local blade failed to power off upon request. Probable Cause: This blade has
failed to power off. Recommended Action: Try resetting iLO and attempting power
off again. WBEM EventID: 10175. WBEM ProviderName: FPL_IndicationProvider.Warning14748
The system has failed to power off upon request. Probable Cause: the rack or one or
more blades have failed to power off. The overall power off action has failed as a
result. Recommended Action: reset iLO and attempt power off again. WBEM EventID:
10176. WBEM ProviderName: FPL_IndicationProvider.Warning14749
A data table stored in non-volatile RAM is invalid. Probable Cause: Manageability
or System FW revisions are out of date or corrupted. Recommended Action: Ensure
that all firmware is at the correct supported version. WBEM EventID: 10223. WBEM
ProviderName: FPL_IndicationProvider.Warning14812
The system has lost AC power. Probable Cause: Most likely cause is removal of an
AC power cord, or a bulk power supply failure. Recommended Action: Make sure
that the AC Power cord is properly installed, and the bulk power supply is functional.
WBEM EventID: 10359. WBEM ProviderName: FPL_IndicationProvider.Error14841
The chassis has been open for an extended period of time. Probable Cause: The chassis
dorr or top cover is open. More specifically it has been open for an extended period
of time. Recommended Action: Close the door or top cover. WBEM EventID: 10405.
WBEM ProviderName: FPL_IndicationProvider.Error14843
The Power Button was asserted prior to changing the system power. Probable Cause:
The power button must be released before remotely controlling system power. The
button may be stuck. Recommended Action: Inspect the power button and correct
anything which may affect its proper operation. WBEM EventID: 10366. WBEM
ProviderName: FPL_IndicationProvider.Warning14854
ICH failed to respond to an i2c query. Probable Cause: The ICH device failed to
respond to an i2c request. It is probable that the ICH device is in a failed state.
Recommended Action: Investigate the ICH MEZZ card to determine if there has been
a failure. WBEM EventID: 10384. WBEM ProviderName: FPL_IndicationProvider.Warning14876
Hardware configuration exceeds available power. Probable Cause: Power supply
has limited capability and detected hardware configuration exceeds the power
capability. Recommended Action: Reduce the hardware configuration, or connect
power supplies to higher voltage. WBEM EventID: 10550. WBEM ProviderName:
FPL_IndicationProvider.Error14878
Excessive processor corrected errors. Probable Cause: Processor module is failing or
failed. Recommended Action: Replace the processor module. WBEM EventID: 10398.
WBEM ProviderName: FPL_IndicationProvider.Warning14909