HP Insight Management WBEM Provider Events Reference Guide

Generic trap for Critical or Fatal type E0 event from system firmware. Probable Cause:
This event is generated when a critical or fatal event has occurred as reported by
system firmware. The server is not operational and is in a state where it cannot
provide more details about the failure. To obtain more information, log into the
server's Management Processor Card and look at the event log for more details on
the failure. Recommended Action: Contact HP Support for best course of action. HP
may require a reboot, reconfiguration, or reflash of firmware. WBEM EventID: 162.
WBEM ProviderName: SEL02_IndicationProvider.Error15070
INIT Initiated. Probable Cause: The critical interrupt sensor has detected that there
was a Diagnostic Interrupt initiated by IPMI command. Either the Transfer Of Control
(TOC) button was pressed or the interrupt was initiated remotely. The system will
reboot after the interrupt processing is finished. Recommended Action: If this is
unexpected behavior, then check logs for events that would have caused an INIT,
TOC, or RESET. WBEM EventID: 170. WBEM ProviderName:
SEL02_IndicationProvider.Error15073
Voltage insufficient. Probable Cause: The input voltage for the system is not sufficient
for operation. Recommended Action: Check all boards, power supplies, and modules
that either supply or use this voltage rail. WBEM EventID: 118. WBEM ProviderName:
SEL02_IndicationProvider.Warning15077
Voltage reached critical level. Probable Cause: The voltage in the server has gone
outside the factory set range. A bad component, blown fuse, poorly seated module,
loose cable, or debris could be responsible for this failure. Recommended Action:
When this condition was detected the system should have been immediately
shutdown to avoid damage. Contact your HP support representative as soon as
possible to have the unit checked. Check all boards, power supplies, and modules
that either supply or use this voltage rail. WBEM EventID: 120. WBEM ProviderName:
SEL02_IndicationProvider.Error15078
Voltage absent. Probable Cause: There is either a missing or failed power component.
This may be a normal message when a system is not loaded to capacity and power
components are purposefully left out of the system. Recommended Action: If this is
unexpected, then check all boards, power supplies, and modules that either supply
or use this voltage rail. WBEM EventID: 122. WBEM ProviderName:
SEL02_IndicationProvider.Warning15079
Fan speed lags. Probable Cause: Possibly, the specified fan is beginning to lose
performance. Recommended Action: If these errors continue to be reported, the fan
should be replaced. WBEM EventID: 126. WBEM ProviderName:
SEL02_IndicationProvider.Warning15082
OS run-time critical shutdown. Probable Cause: The OS caused the system to shut
down. Recommended Action: Look at OS logs and crash data to determine why the
system shut down. WBEM EventID: 175. WBEM ProviderName:
SEL02_IndicationProvider.Error15092
Power supply failure. Probable Cause: The system has detected that one of the power
supplies has failed. Recommended Action: The power cable has been disconnected.
Reconnect, or The power supply has failed. Contact your HP support representative
to check the power supply. WBEM EventID: 137. WBEM ProviderName:
SEL02_IndicationProvider.Warning15093
Power supply AC lost. Probable Cause: The power supply has lost its A/C source.
The power supply is not connected to a working A/C power source. Recommended
Action: Verify that the plug is connected to the power supply, and to a working
power source. WBEM EventID: 139. WBEM ProviderName: SEL02_IndicationProvider.Warning15094
Cooling unit warning. Probable Cause: The Cooling Unit may be running properly
now, but it was detected in a degraded state. It may need to be replaced in the future.
Recommended Action: Continue to monitor unit and contact HP support to determine
appropriate action. WBEM EventID: 157. WBEM ProviderName:
SEL02_IndicationProvider.Warning15103
Cooling unit failure. Probable Cause: A cooling unit has failed. Recommended Action:
Replace the indicated cooling unit. WBEM EventID: 158. WBEM ProviderName:
SEL02_IndicationProvider.Error15104
104 WBEM Provider Event Tables