HP Insight Management WBEM Provider Events Reference Guide
Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The
temperature inside the server has gone far outside the factory specified range for
normal operation. To avoid permanent damage to your server hardware, go and
turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Shutdown the system
immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 102.
WBEM ProviderName: SEL02_IndicationProvider.Error15734
One of the temperature sensors crossed its upper non-critical threshold. Probable
Cause: The temperature inside the server has gone outside the factory specified range
for normal operation. This event may indicate one of the following conditions: a
failed fan blocked air vents or poor ventilation around the server open server chassis
cover, or missing drive slot covers high temperature in the room where the server
resides an unusually hot hardware component located near one of the server's
temperature sensors. Recommended Action: You should quit applications and
shutdown the system.Find cause of temperature anomaly and fix it. WBEM EventID:
107. WBEM ProviderName: SEL02_IndicationProvider.Warning15735
A temperature inside the server went far outside the factory specified range. Probable
Cause: The temperature inside the server has gone far outside the factory specified
range for normal operation. To avoid permanent damage to your server hardware,
go and turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Shutdown the system
immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 108.
WBEM ProviderName: SEL02_IndicationProvider.Error15736
The AC voltage to the power supply was lost or is out of range. Probable Cause: The
AC voltage was lost, or is the wrong range for the system. Recommended Action:
Verify the power supply is plugged in to the proper voltage for the system. WBEM
EventID: 140. WBEM ProviderName: SEL02_IndicationProvider.Warning15737
The power supply AC voltage is out of range. Probable Cause: The AC voltage is
connected to the power supply, but it is not the voltage range required for the system.
Recommended Action: Connect the power supply to the proper voltage range. WBEM
EventID: 141. WBEM ProviderName: SEL02_IndicationProvider.Warning15738
HP Ethernet Events
Source in Windows Event Log: HP Ethernet
Event DescriptionEvent
Severity
Event
ID
An Ethernet provider encountered an unrecoverable error.Error1
A network interface has failed. An Ethernet adapter's status changed from OK to
Error, or an Ethernet team's status changed to Error from another state.
Error
2
A failed network interface was restored. An Ethernet port's status changed from an
Error state to a non-Error state.
Information
3
An Ethernet team's redundancy has decreased. A team member has changed to failed
or degraded state.
Warning
4
An Ethernet team's redundancy status changed to Redundancy Lost. All members
of an Ethernet team, except one, are failed.
Error
5
An Ethernet team's redundancy has increased. A team member recovered from a
failed or degraded state.
Information
6
HP Ethernet Events 107