HP Insight Management WBEM Provider Events Reference Guide

A new team member has been added to an Ethernet team via the HP Network
Configuration Utility (NCU). This is an optional indication that can be disabled via
the Ethernet Event Provider settings.
Information
7
A team member was dropped from the team via the HP Network Configuration
Utility (NCU). This is an optional indication that can be disabled via the Ethernet
Event Provider settings.
Information
8
An Ethernet Team member's role has changed. This is an optional indication that can
be disabled via the Ethernet Event Provider settings.
Information
9
An Ethernet team member's status has changed. This is an optional indication that
can be disabled via the Ethernet Event Provider settings.
Information
10
A new network interface is available. An Ethernet adapter has been added or an
Ethernet team or VLAN has been created. This is an optional indication that can be
disabled via the Ethernet Event Provider settings.
Information
11
A network interface is no longer available. An Ethernet adapter was removed or an
Ethernet team or VLAN was removed via the HP Network Configuration Utility
(NCU).
Warning
12
The number of active adapters in an Ethernet team has changed. This is an optional
indication that can be disabled via the Ethernet Event Provider settings.
Information
13
The event provider encountered a non-fatal error. Some information may not be
available.
Warning
14
An Ethernet team's redundancy status changed to Fully Redundant. An Ethernet
team member status changed from Error or Degraded to OK.
Information
15
HP Fiber Channel Events
Source in Windows Event Log: HP Fiber Channel
Event DescriptionEvent
Severity
Event ID
This fiber channel HBA port has returned to a status of OK.Information2
A fiber channel HBA port has changed to a state of link down.Error6
HP SAS Events
Source in Windows Event Log: HP SAS
Event DescriptionEvent
Severity
Event
ID
A SAS/SATA HBA status has changed from non-OK to OK.Information1
A SAS/SATA HBA status has changed to Error.Error2
A logical drive status has changed from non-OK to OK.Information101
A logical drive status has changed to Error.Error102
A logical drive is in a degraded state. Device is still servicing I/O, but redundancy
may be degraded or lost.
Warning
103
A physical drive status has changed from non-OK to OK.Information201
A physical drive status has changed to Error.Error202
A physical drive status has changed to Rebuilding. Data is now being rebuilt onto
this drive from the RAID set.
Information
203
A physical drive status has changed to Predictive Failure.Warning204
108 WBEM Provider Event Tables