A Storage Enclosure Power Subsystem status has changed to non-redundant.Warning301
A Storage Enclosure Power Supply has changed to Fully Redundant.Information302
A Storage Enclosure Power Supply status has changed to Degraded Redundancy.Warning303
A Storage Enclosure Fan status has changed from a non-OK state to OK.Information304
A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected
there may a problem with one or more of the fans.
Warning
305
A Storage Enclosure Fan status changed to Failure. An enclosure has detected a
failure in the fan subsystem and there is insufficient fan capability to ensure normal
operation.
Error
306
A Storage Enclosure Temperature sensor status changed from non-OK to OK.Information307
A Storage Enclosure Temperature sensor status changed to Warning Condition. This
indicates the enclosure temperature is above normal, otherwise enclosure is still
operating normally.
Warning
308
A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure
temperature is reaching the maximum allowed temperature for normal operation.
A shutdown is imminent. Action is required before loss of data occurs.
Error
309
HP SCSI Events
Source in Windows Event Log: HP SCSI
Event DescriptionEvent
Severity
Event
ID
A SCSI device status has changed to Unknown.Information1
This SCSI HBA status has changed from non-OK to OK.Information2
A SCSI HBA status has changed to Error.Error3
A SCSI physical drive status has changed from non-OK to OK.Information4
A SCSI physical drive has a status of Error.Error5
A SCSI physical drive with a status of OK that was located in the system has been
removed.
Information
6
A SCSI physical drive with a status of Error that was located in the system has been
removed.
Information
7
A SCSI physical drive status is now set to Predictive Failure.Error8
A SCSI physical drive with a status of Predictive Failure that was located in the
system has been removed.
Information
9
A SCSI physical drive is offline and can no longer return data. No further status is
available.
Error
10
A SCSI physical drive that was located in the system and had a status of offline has
been removed.
Information
11
A Storage Enclosure Power Supply status has changed to non-redundant.Error301
A Storage Enclosure Power Supply has changed to Fully Redundant.Information302
A Storage Enclosure Power Supply status has changed to Degraded Redundancy.Warning303
The storage enclosure fan subsystem is operating properly.Information304
A fan has failed, but there are enough fans in the fan subsystem to keep the enclosure
cool.
Warning
305