HP Insight Management WBEM Provider Events Reference Guide

A fan has failed and there are not enough fans in the fan subsystem to keep the
enclosure cool.
Error
306
A Storage Enclosure Temperature sensor status changed from non-OK to OK.Information307
A Storage Enclosure Temperature sensor Status changed to Warning Condition. This
indicates the enclosure temperature is above normal, otherwise enclosure is still
operating normally.
Warning
308
A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure
temperature is reaching the maximum allowed temperature for normal operation.
A shutdown is imminent. Action is required before loss of data occurs.
Error
309
HP Smart Array Events
Source in Windows Event Log: HP Smart Array
Event DescriptionEvent
Severity
Event
ID
A Smart Array controller status has changed from non-OK to OK.Warning1
A Smart Array controller status has changed to Error.Error2
A Smart Array controller redundancy state has changed from Standby to Active.Warning3
A Smart Array controller has detected that redundancy has been lost due to failure
or loss of communication with partner controller.
Warning
4
Controller has detected that Redundancy has been restored and can communicate
with partner controller.
Information
5
A Smart Array controller Battery status has changed from non-OK to OK.Information6
A Smart Array controller Battery status has changed to Not Fully Charged.Warning7
A Smart Array controller battery status changed to Failed.Error8
A Smart Array controller Cache status has changed from non-OK to OK.Information9
A Smart Array controller Cache status has changed to Temporarily Disabled. This
may be caused by a rebuild or configuration change. Normal operation will return
after background operations have completed.
Information
10
A Smart Array controller Cache status has changed to Permanently Disabled. The
controller has detected a problem with the cache and has disabled the cache
permanently.
Warning
11
A logical drive status has changed from a non-OK state to OK.Information101
A logical drive status has changed to Error.Error102
A logical drive is in a degraded state. Device is still servicing I/O but redundancy
may be degraded or lost.
Warning
103
A physical drive status has changed from a non-OK state to OK.Information201
A physical drive status has changed to Error.Error202
A physical drive status has changed to Rebuilding. Data is now being rebuilt onto
this drive from the RAID set.
Information
203
A physical drive status has changed to Predictive Failure.Error204
A Storage Enclosure Power Subsystem status has changed to non-redundant.Warning301
A Storage Enclosure Power Supply has changed to Fully Redundant.Information302
A Storage Enclosure Power Supply status has changed to Degraded Redundancy.Warning303
A Storage Enclosure Fan status has changed from a non-OK state to OK.Information304
110 WBEM Provider Event Tables