Event DescriptionEvent
Severity
Event ID
PCI parity error detected. Probable Cause: An I/O device (or host bridge) detected a
bus parity error, OR An I/O device (or host bridge) mastered a bus transaction and
received a parity error response from the target. Recommended Action: For an I/O
bus parity error, consult the error logs for additional information. Determine and
replace the failed I/O device. For an I/O host bridge failure, contact your HP
representative to check the I/O host bridge. WBEM EventID: 171. WBEM
ProviderName: SEL02_IndicationProvider.Warning751
Temperature sensor crossed upper non-critical threshold. Probable Cause: The
temperature inside the server has gone outside the factory specified range for normal
operation. You should quit applications and power down the server to protect its
hardware from damage. This event may indicate one of the following conditions: A
failed fan, blocked air vents or poor ventilation around the server, open server chassis
cover, or missing drive slot covers, high temperature in the room where the server
resides, an unusually hot hardware component located near one of the server's
temperature sensors. Recommended Action: You should quit applications and
shutdown the system. Find cause of temperature anomaly and fix it. WBEM EventID:
100. WBEM ProviderName: SEL02_IndicationProvider.Warning752
A temperature inside the server went far outside the factory specified range. Probable
Cause: The temperature inside the server has gone far outside the factory specified
range for normal operation. To avoid permanent damage to your server hardware,
go and turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Shutdown the system
immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 101.
WBEM ProviderName: SEL02_IndicationProvider.Error753
Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The
temperature inside the server has gone far outside the factory specified range for
normal operation. To avoid permanent damage to your server hardware, go and
turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Shutdown the system
immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 102.
WBEM ProviderName: SEL02_IndicationProvider.Error754
One of the temperature sensors crossed its upper non-critical threshold. Probable
Cause: The temperature inside the server has gone outside the factory specified range
for normal operation. This event may indicate one of the following conditions: a
failed fan blocked air vents or poor ventilation around the server open server chassis
cover, or missing drive slot covers high temperature in the room where the server
resides an unusually hot hardware component located near one of the server's
temperature sensors. Recommended Action: You should quit applications and
shutdown the system.Find cause of temperature anomaly and fix it. WBEM EventID:
107. WBEM ProviderName: SEL02_IndicationProvider.Warning755
A temperature inside the server went far outside the factory specified range. Probable
Cause: The temperature inside the server has gone far outside the factory specified
range for normal operation. To avoid permanent damage to your server hardware,
go and turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Shutdown the system
immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 108.
WBEM ProviderName: SEL02_IndicationProvider.Error756
12 WBEM Provider Event Tables