HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
Found unexpected I/O host bridge. Probable Cause: The firmware needs to be
updated. An incorrect I/O backplane is installed. Recommended Action: Update
SFW. If problem persists, contact your HP representative to check the I/O backplane.
WBEM EventID: 271. WBEM ProviderName: FPL_IndicationProvider.Warning5127
PCI clock DLL error. Probable Cause: Failed I/O chipset. Failed I/O backplane.
Recommended Action: Contact your HP representative to check the I/O chipset and
backplane. WBEM EventID: 272. WBEM ProviderName: FPL_IndicationProvider.Warning5130
PCI hot plug controller failed. Probable Cause: Hot-plug controller failure. I/O host
bridge failure. Recommended Action: Contact your HP representative to check the
hot-plug controller and the I/O host bridge. WBEM EventID: 273. WBEM
ProviderName: FPL_IndicationProvider.Warning5131
Found unknown I/O rope width. Probable Cause: Internal firmware error.
Recommended Action: Contact your HP representative to check the firmware. WBEM
EventID: 274. WBEM ProviderName: FPL_IndicationProvider.Warning5132
I/O LBA clear error failed. Probable Cause: A failed or improperly seated I/O card is
present. Recommended Action: Replace or reseat the I/O card(s). WBEM EventID:
275. WBEM ProviderName: FPL_IndicationProvider.Warning5133
I/O host bridge inaccessible because rope reset failed to complete. Probable Cause:
I/O CEC failure. Recommended Action: Contact your HP representative to check the
I/O CEC. WBEM EventID: 276. WBEM ProviderName: FPL_IndicationProvider.Warning5136
Insufficient power to turn on PCI slot. Probable Cause: The power budget for the IO
subsystem has been exceeded. Recommended Action: The IO config in the system
is unsupported. Verify that the IO config installed in the system is one that is
supported. If problem persists contact your HP representative for support. WBEM
EventID: 277. WBEM ProviderName: FPL_IndicationProvider.Warning5137
PCI bus walk unknown error. Probable Cause: Internal firmware error. Recommended
Action: Contact your HP representative to check the firmware. WBEM EventID: 278.
WBEM ProviderName: FPL_IndicationProvider.Warning5138
PCI bus walk resources exceeded. Probable Cause: Unsupported I/O configuration.
Recommended Action: Remove any unsupported I/O cards. Move the I/O card to
another slot. WBEM EventID: 279. WBEM ProviderName: FPL_IndicationProvider.Warning5139
PCI bus unmap unknown error. Probable Cause: Internal firmware error.
Recommended Action: Contact your HP representative to check the firmware. WBEM
EventID: 280. WBEM ProviderName: FPL_IndicationProvider.Warning5140
PCIXCAP sampling error. Probable Cause: I/O host bridge failure. Recommended
Action: Contact your HP representative to check the I/O host bridge. WBEM EventID:
281. WBEM ProviderName: FPL_IndicationProvider.Warning5141
Power monitor failed to respond. Probable Cause: BMC failure. Recommended
Action: Contact your HP representative to check the BMC. WBEM EventID: 282.
WBEM ProviderName: FPL_IndicationProvider.Warning5142
I/O rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended
Action: Reboot. If problem persists, contact your HP representative to check the I/O
controller. WBEM EventID: 283. WBEM ProviderName: FPL_IndicationProvider.Warning5143
I/O SBA clear error failed. Probable Cause: I/O chipset failure. Recommended Action:
Contact your HP representative to check the I/O chipset. WBEM EventID: 284. WBEM
ProviderName: FPL_IndicationProvider.Warning5144
PCI slot has incorrect default power state. Probable Cause: The hot-plug controller
has failed. Recommended Action: Contact your HP representative to check the
hot-plug slot. WBEM EventID: 285. WBEM ProviderName: FPL_IndicationProvider.Warning5145
PCI slot power on error. Probable Cause: The I/O card is damaged or improperly
inserted. Recommended Action: Replace or reseat the I/O card. WBEM EventID: 286.
WBEM ProviderName: FPL_IndicationProvider.Warning5146
18 WBEM Provider Event Tables