HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
DIMM SPD fatal error. Probable Cause: Detection of SPD error type - various types.
Recommended Action: Reseat or replace the DIMM. If problem persists, contact HP
Support personnel to troubleshoot the problem. WBEM EventID: 302. WBEM
ProviderName: FPL_IndicationProvider.Warning5173
Unsupported memory DIMM type. Probable Cause: A DIMM with an invalid DIMM
type was found. Recommended Action: Contact HP Support personnel to troubleshoot
the problem. WBEM EventID: 303. WBEM ProviderName: FPL_IndicationProvider.Warning5174
The DIMM type of this DIMM doesn't match with others in the DIMM group. Probable
Cause: The DIMMs in the rank do not have the same DIMM type. Recommended
Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID:
304. WBEM ProviderName: FPL_IndicationProvider.Warning5175
The DIMM type table is full. New DIMM type cannot be added. Probable Cause: Too
many different types of DIMMs in system. Recommended Action: Reduce the number
of different types of DIMMs in the system. WBEM EventID: 305. WBEM
ProviderName: FPL_IndicationProvider.Warning5176
DIMM number not found in DMT Table. Probable Cause: Probable internal FW error.
Recommended Action: Reload System Firmware. Recommended Action: Contact
HP Support personnel to troubleshoot the problem. WBEM EventID: 306. WBEM
ProviderName: FPL_IndicationProvider.Warning5179
Memory ECC multiple-bit data error detection failed. Probable Cause: The CEC failed
MBE detection. Recommended Action: Contact HP support personnel to troubleshoot
the problem. WBEM EventID: 307. WBEM ProviderName: FPL_IndicationProvider.Warning5180
Memory ECC multiple-bit ECC error signalling failed. Probable Cause: The CEC
failed MBE detection. Recommended Action: Contact HP support personnel to
troubleshoot the problem. WBEM EventID: 308. WBEM ProviderName:
FPL_IndicationProvider.Warning5181
Memory ECC single-bit data error detection failed. Probable Cause: The CEC failed
SBE detection. Recommended Action: Contact HP support personnel to troubleshoot
the problem. WBEM EventID: 309. WBEM ProviderName: FPL_IndicationProvider.Warning5182
Memory ECC single-bit ECC error detection failed. Probable Cause: The CEC failed
SBE detection. Recommended Action: Contact HP support personnel to troubleshoot
the problem. WBEM EventID: 310. WBEM ProviderName: FPL_IndicationProvider.Warning5183
Memory address not found in MBAT. Probable Cause: The address logged in the
CEC doesn't map to a memory rank, possibly due to a SFW error or NVM corruption.
Recommended Action: Contact HP support to troubleshoot the problem. WBEM
EventID: 312. WBEM ProviderName: FPL_IndicationProvider.Warning5186
Memory Error Information not cleared. Probable Cause: Software Error or CEC error.
Recommended Action: Contact HP support to troubleshoot the problem. WBEM
EventID: 313. WBEM ProviderName: FPL_IndicationProvider.Warning5187
Couldn't clear memory error logs. Probable Cause: SFW Error or CEC error.
Recommended Action: Contact HP support to troubleshoot the problem. WBEM
EventID: 314. WBEM ProviderName: FPL_IndicationProvider.Warning5189
Memory error clear failed. Probable Cause: SFW error or CEC error. Recommended
Action: Contact HP support to troubleshoot the problem. WBEM EventID: 315. WBEM
ProviderName: FPL_IndicationProvider.Warning5190
DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM
is not loaded in order to allow for proper operation of the DIMM specified in the
physical location. Recommended Action: Refer to the user's manual for Memory
loading instructions. WBEM EventID: 316. WBEM ProviderName:
FPL_IndicationProvider.Warning5191
Generic memory firmware error. Probable Cause: Corrupt NVM or System firmware
failure. Recommended Action: Contact HP support to troubleshoot the problem.
WBEM EventID: 317. WBEM ProviderName: FPL_IndicationProvider.Warning5193