HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
Memory fetch timeout. Probable Cause: SBA memory fetch timeout error.
Recommended Action: repair faulty hardware. WBEM EventID: 379. WBEM
ProviderName: FPL_IndicationProvider.Error5447
Error was encountered when Initializing the LBA. Probable Cause: LBA firmware
initialization failed. Recommended Action: Review additional error logs to determine
exact cause of failure. WBEM EventID: 380. WBEM ProviderName:
FPL_IndicationProvider.Error5448
LBA correctable Timeout Error was encountered. Probable Cause: An LBA correctable
timeout error occurred. Recommended Action: No action necessary, the error was
corrected. Information only. WBEM EventID: 381. WBEM ProviderName:
FPL_IndicationProvider.Warning5449
LBA uncorrectable Function Error was encountered. Probable Cause: An LBA
uncorrectable function error was encountered. Recommended Action: Replace/repair
faulty hardware. WBEM EventID: 382. WBEM ProviderName:
FPL_IndicationProvider.Error5450
LBA uncorrectable Timeout Error was encountered. Probable Cause: LBA
uncorrectable timeout error encountered. Recommended Action: Repair/replace
faulty hardware. WBEM EventID: 383. WBEM ProviderName:
FPL_IndicationProvider.Error5451
Misc. uncorrectable error discovered on LBA. Probable Cause: LBA uncorrectable
error encountered. Recommended Action: Repair/replace faulty hardware. WBEM
EventID: 384. WBEM ProviderName: FPL_IndicationProvider.Error5452
LBA encountered an uncorrectable parity error. Probable Cause: LBA encountered
an uncorrectable parity error. Recommended Action: Repair/replace faulty hardware.
WBEM EventID: 385. WBEM ProviderName: FPL_IndicationProvider.Error5453
LBA Misc. Fatal Error encountered. Probable Cause: LBA fatal error encountered.
Recommended Action: Repair/replace the faulty hardware. WBEM EventID: 386.
WBEM ProviderName: FPL_IndicationProvider.Error5454
LBA Fatal function error encountered. Probable Cause: An LBA fatal function error
was encountered. Recommended Action: Repair/replace the faulty hardware. WBEM
EventID: 387. WBEM ProviderName: FPL_IndicationProvider.Error5455
LBA Fatal Parity error encountered. Probable Cause: An LBA fatal parity error
encountered. Recommended Action: Repair/replace the faulty hardware. WBEM
EventID: 388. WBEM ProviderName: FPL_IndicationProvider.Error5456
LBA Fatal Timeout Error Encountered. Probable Cause: LBA fatal timeout error
encountered. Recommended Action: Repair/replace the faulty hardware. WBEM
EventID: 389. WBEM ProviderName: FPL_IndicationProvider.Error5457
Misc Uncorrectable Error encountered. Probable Cause: A PCI card uncorrectable
error was encountered. Recommended Action: Replace the faulty PCI card. WBEM
EventID: 2424. WBEM ProviderName: FPL_IndicationProvider.Error5458
Misc fatal error discovered on PCI card. Probable Cause: A fatal error was detected
on a PCI card. Recommended Action: Repair/replace the faulty PCI card. WBEM
EventID: 2425. WBEM ProviderName: FPL_IndicationProvider.Error5459
DIMM SPD Extended Checksum Failure. Probable Cause: Replace any bad dimms.
WBEM EventID: 392. WBEM ProviderName: FPL_IndicationProvider.Error5464
The DIMM has been hardware deallocated. Probable Cause: Memory error occurred
in main memory. Recommended Action: Replace all DIMMs as specified by physical
location, followed by the Extended Memory Buffer (EMB). WBEM EventID: 8034.
WBEM ProviderName: FPL_IndicationProvider.Warning5466
Options header checksum error encountered. Probable Cause: Reinitialize the options
data. WBEM EventID: 393. WBEM ProviderName: FPL_IndicationProvider.Warning5467
Platform Events 25