HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
Options data checksum error was encountered. Probable Cause: Verify options data
and reinitialize if necessary. WBEM EventID: 394. WBEM ProviderName:
FPL_IndicationProvider.Warning5468
Internal inconsistency in the interleave tables. Probable Cause: Reconfigure and Reset.
WBEM EventID: 395. WBEM ProviderName: FPL_IndicationProvider.Error5473
CellInfoList is not NULL. Probable Cause: Reset. WBEM EventID: 396. WBEM
ProviderName: FPL_IndicationProvider.Warning5474
Error in constructing the Memory Descriptor. Probable Cause: Reset. WBEM EventID:
397. WBEM ProviderName: FPL_IndicationProvider.Error5478
Unable to update the local memory layout. Probable Cause: Reset. WBEM EventID:
398. WBEM ProviderName: FPL_IndicationProvider.Error5479
A required address was not found within a mapped address. Probable Cause: Reset.
WBEM EventID: 399. WBEM ProviderName: FPL_IndicationProvider.Error5483
Failure to install a Partition level PDT. Probable Cause: Reset. WBEM EventID: 400.
WBEM ProviderName: FPL_IndicationProvider.Error5485
A critical resource could not be found or is unusable. Probable Cause: Determine the
failing component or hardware from the data field as described and replace. WBEM
EventID: 401. WBEM ProviderName: FPL_IndicationProvider.Error5490
Internal firmware programming error. Probable Cause: Report the IP to the firmware
team. Reset the system. This cannot be worked around in the field. WBEM EventID:
402. WBEM ProviderName: FPL_IndicationProvider.Error5491
NVRam test failed with a data compare error. Probable Cause: Bad NVRam, replace
the bad chip. WBEM EventID: 2426. WBEM ProviderName: FPL_IndicationProvider.Error5492
An NVRam CRC Error was detected. Probable Cause: Firmware/software error.
Recommended Action: Check for new version of firmware/OS Contact HP Support.
WBEM EventID: 2427. WBEM ProviderName: FPL_IndicationProvider.Error5493
The Error Response Mode has been determined. Probable Cause: Decode the hex
vales to ASCII to determine the mode. Other errors will determine action. WBEM
EventID: 4523. WBEM ProviderName: FPL_IndicationProvider.Warning5494
A semaphore could not be obtained. Probable Cause: Semaphore error. Recommended
Action: Reset system to clear the semaphore Try reinitializing NVRAM. If problem
persists, contact engineering. WBEM EventID: 405. WBEM ProviderName:
FPL_IndicationProvider.Error5496
The BLOCK requested in NVRAM has the wrong revision. Probable Cause: Clear
NVRAM and reset. WBEM EventID: 2428. WBEM ProviderName:
FPL_IndicationProvider.Error5498
The requested NVRAM block was not found. Probable Cause: No Action Required.
Firmware can allocated space for the block. WBEM EventID: 407. WBEM
ProviderName: FPL_IndicationProvider.Warning5499
The requested NVRAM block is locked. Probable Cause: Retry the operation. WBEM
EventID: 408. WBEM ProviderName: FPL_IndicationProvider.Warning5500
Firmware tried to unlock a NVRAM block that was already unlocked. Probable
Cause: No action required. WBEM EventID: 409. WBEM ProviderName:
FPL_IndicationProvider.Warning5501
The Header in NVRAM was not found. Probable Cause: NVRAM cannot be used. It
must be initialized first. Firmware will attempt the initialization. WBEM EventID:
410. WBEM ProviderName: FPL_IndicationProvider.Error5502
The Freelist used for NVM block allocation is corrupt. Probable Cause: Bad NVRAM/
reinitialize. WBEM EventID: 411. WBEM ProviderName: FPL_IndicationProvider.Error5503
26 WBEM Provider Event Tables