HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
ROM revision not equal to Rev block. Probable Cause: A ROM Rev and Rev Block
do not match. Recommended Action: Update SFW, if problem persists contact your
HP representative for support. WBEM EventID: 584. WBEM ProviderName:
FPL_IndicationProvider.Warning5602
Primary Fit bad. Probable Cause: The FIT is bad. Recommended Action: Reboot,
update SFW if necessary, if problem persists contact your HP representative for
support. WBEM EventID: 585. WBEM ProviderName: FPL_IndicationProvider.Warning5603
Secondary Fit bad. Probable Cause: The FIT is bad. Recommended Action: Reboot,
update SFW if necessary, if problem persists contact your HP representative for
support. WBEM EventID: 586. WBEM ProviderName: FPL_IndicationProvider.Warning5604
PAL A execution rom warning. Probable Cause: PAL_A_ROM has generated a
warning. Recommended Action: Reboot, update SFW if necessary, if problem persists
contact your HP representative for support. WBEM EventID: 587. WBEM
ProviderName: FPL_IndicationProvider.Warning5605
PAL B execution rom warning. Probable Cause: PAL_B_ROM has generated a
warning. Recommended Action: Reboot, update SFW if necessary, if problem persists
contact your HP representative for support. WBEM EventID: 588. WBEM
ProviderName: FPL_IndicationProvider.Warning5606
An error was encountered when firmware tried to update the Group B Profile.
Probable Cause: Utilities may be unavailable to update the profiles. Check the
connections are reset. WBEM EventID: 1030. WBEM ProviderName:
FPL_IndicationProvider.Error5607
PCI parity error detected. Probable Cause: I/O host bridge failure. Recommended
Action: Contact your HP representative to check the I/O host bridge. WBEM EventID:
430. WBEM ProviderName: FPL_IndicationProvider.Warning5617
PCI system error detected. Probable Cause: I/O device failure. Recommended Action:
Consult the error logs for additional information. Determine and replace the failed
I/O device. WBEM EventID: 431. WBEM ProviderName: FPL_IndicationProvider.Warning5618
I/O host bridge is deconfigured. Probable Cause: See earlier error event.
Recommended Action: See earlier error event. WBEM EventID: 432. WBEM
ProviderName: FPL_IndicationProvider.Warning5619
Firmware was unable to publish the Partition Profile. Probable Cause: Utilities may
be unavailable to update the profiles. Check the connections are reset. WBEM EventID:
1008. WBEM ProviderName: FPL_IndicationProvider.Error5621
The reporting cell is not configured to be in a PD. Probable Cause: Run parmgr to
configure the cell into a PD and reset the PD or add the cell. WBEM EventID: 434.
WBEM ProviderName: FPL_IndicationProvider.Error5622
DIMM thermal loading order warning. Probable Cause: The current DIMM loading
order does not follow the guidelines in the user manual. Recommended Action:
Rearrange the DIMMs to follow the loading order specified in the Maintenance and
Operation Manual. WBEM EventID: 435. WBEM ProviderName:
FPL_IndicationProvider.Warning5623
The PD cannot boot, a majority of cells did not arrive at Rendezvous. Probable Cause:
PD Rendezvous Boot Rules: If greater than 50% of the assigned cells are rendezvoused,
we will boot. If less than 50% of the assigned cells are rendezvoused, don't boot. If
exactly 50% of the assigned cells are rendezvoused, including all of the preferred
core cells, we will boot. If exactly 50% have rendezvoused, and there is a specified
preferred core cell not rendezvoused, don't boot. If exactly 50% have rendezvoused,
and there are no preferred core cells, don't boot. If any of the above apply in
preventing the boot. Reconfigure the PD and reboot. WBEM EventID: 437. WBEM
ProviderName: FPL_IndicationProvider.Error5626
30 WBEM Provider Event Tables