HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
MC_RENDEZVOUS: Get PAL features failed. Probable Cause: PAL does not support
call to get the processor feature set during processor rendezvous. Recommended
Action: Update system firmware with a new PAL that support the
PAL_GET_FEATURES call. WBEM EventID: 451. WBEM ProviderName:
FPL_IndicationProvider.Warning5685
MC_RENDEZVOUS: Set PAL features failed. Probable Cause: PAL does not support
call to set the processor feature set during processor rendezvous. Recommended
Action: update system firmware with new PAL that support the PAL_SET_FEATURE
call. WBEM EventID: 452. WBEM ProviderName: FPL_IndicationProvider.Warning5686
Internal Firmware Programming Error from the EFI portion of the firmware. Probable
Cause: Report the IP to the firmware team. Reset the system. This cannot be worked
around in the field. WBEM EventID: 453. WBEM ProviderName:
FPL_IndicationProvider.Error5692
memory extender loading order error. Probable Cause: The memory extenders have
not been loaded in the correct order. Recommended Action: Load the Memory
extenders according to the users manual. WBEM EventID: 454. WBEM ProviderName:
FPL_IndicationProvider.Error5696
Inconsistency in the length of the ESI table. Probable Cause: Table entries corrupted.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 455. WBEM ProviderName: FPL_IndicationProvider.Error5698
The computed checksum for ESI Table incorrect. Probable Cause: Table corrupted.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 456. WBEM ProviderName: FPL_IndicationProvider.Error5700
ESI Table contains an unsupported entry type. Probable Cause: Corrupted table.
Recommended Action: Reboot system. If problem persists, contact HP support to
troubleshoot the problem. WBEM EventID: 457. WBEM ProviderName:
FPL_IndicationProvider.Warning5701
A GUID was larger than the expected 128 bits. Probable Cause: Inconsistency in EFI
firmware. Recommended Action: Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem. WBEM EventID: 458. WBEM
ProviderName: FPL_IndicationProvider.Warning5704
EFI is halting. Probable Cause: Unknown. Recommended Action: examine preceding
events for problem. WBEM EventID: 459. WBEM ProviderName:
FPL_IndicationProvider.Error5708
chipspare not supported on quad. Probable Cause: User installed a x8 DIMM in a
system configured for chipspare. Recommended Action: If user requires Chipspare,
replace the DIMM with a x4 DIMM. If Chipspare is not required, then no action is
required. WBEM EventID: 460. WBEM ProviderName: FPL_IndicationProvider.Warning5711
EFI internal error detected resulting in execution of ASSERT macro. Probable Cause:
The cause is unknown. Recommended Action: Look at previous events and ASCII
information in this event for more information. If problem persists, contact HP support
to troubleshoot the problem. WBEM EventID: 461. WBEM ProviderName:
FPL_IndicationProvider.Warning5712
EFI has executed the 'break' shell command. Probable Cause: Executing the 'break'
command. Recommended Action: Check for user entering 'break' command. Check
for shell scripts using the 'break' command. WBEM EventID: 462. WBEM
ProviderName: FPL_IndicationProvider.Error5713
EFI USB HCD interrupt service has detected the host controller is hung. Probable
Cause: Problem with USB controller. Recommended Action: Reset the card containing
the USB interface to restart the controller. Contact your HP representative to check
the USB interface. WBEM EventID: 463. WBEM ProviderName:
FPL_IndicationProvider.Error5714
32 WBEM Provider Event Tables