HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
The EFI/SAL handoff structure's version does not match EFI expectations. Probable
Cause: EFI/SAL firmware mismatch. Recommended Action: Reboot. If problem
persists contact your HP representative for support. WBEM EventID: 464. WBEM
ProviderName: FPL_IndicationProvider.Error5715
Unable to obtain access to all RTC SAL services. Probable Cause: EFI unable to create
internal event. EFI out of resources. Recommended Action: Reboot. If problem persists
contact your HP representative for support. WBEM EventID: 465. WBEM
ProviderName: FPL_IndicationProvider.Error5717
Unable to obtain access to all SAL timer services. Probable Cause: Not all expected
services are available. Mismatch between EFI and SAL versions. Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 466. WBEM ProviderName: FPL_IndicationProvider.Error5718
EFI unable to start the periodic timer. Probable Cause: Internal system firmware
error. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 467. WBEM ProviderName:
FPL_IndicationProvider.Error5719
No I/O port space region found in the MDT. Probable Cause: EFI/SAL mismatch.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 468. WBEM ProviderName: FPL_IndicationProvider.Error5720
EFI reached an unimplemented section of code. Probable Cause: Reached
unimplemented firmware. Recommended Action: Upgrade system firmware. WBEM
EventID: 469. WBEM ProviderName: FPL_IndicationProvider.Error5721
EFI unable to read current speedy boot settings. Probable Cause: BMC not functioning
properly. Recommended Action: Reset the BMC. Contact your HP representative to
check the BMC. WBEM EventID: 470. WBEM ProviderName: FPL_IndicationProvider.Warning5722
Unpermitted SAL callback attempted. Probable Cause: Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 471. WBEM ProviderName: FPL_IndicationProvider.Error5723
EFI unable to determine frequency base of the CPU interval timer. Probable Cause:
Internal system firmware error. Recommended Action: Upgrade system firmware.
WBEM EventID: 472. WBEM ProviderName: FPL_IndicationProvider.Warning5724
EFI system events already initialized. Probable Cause: Multiple attempts to initialize
system events, EFI internal error. Recommended Action: Upgrade system firmware.
If problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
473. WBEM ProviderName: FPL_IndicationProvider.Warning5725
Unable to create internal virtualization event while initializing IPMI events. Probable
Cause: Out of resources. Internal EFI error. Recommended Action: Reboot system.
Upgrade system firmware. WBEM EventID: 474. WBEM ProviderName:
FPL_IndicationProvider.Warning5726
There was an error creating or initializing the FPGA node in firmware. Probable
Cause: Unable to properly initialize a system firmware node. Recommended Action:
Check for other errors in the system first. Invalidate NVM and retry to boot. Get the
latest firmware release. WBEM EventID: 476. WBEM ProviderName:
FPL_IndicationProvider.Error5728
Error creating the pdh ioconfig node or attaching the service to it. Probable Cause:
This is likely to be a symptom of an earlier problem, or the system is out of malloc
space. Recommended Action: Contact system firmware team. WBEM EventID: 1009.
WBEM ProviderName: FPL_IndicationProvider.Error5729
Error encountered setting up the dillon_pdh node or service. Probable Cause: This
is usually a symptom of an earlier problem. Check to be sure the pdh node was
initialized into the tree correctly. WBEM EventID: 1010. WBEM ProviderName:
FPL_IndicationProvider.Error5730
Platform Events 33