HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
There was an error while initializing the Concorde-Xbc interface. Probable Cause:
An XBC is indicating a port failure. Recommended Action: Validate all of the cells
connectivity to the PD. Check the XBC chips seating reset the system replace either
cells/system backplane. WBEM EventID: 507. WBEM ProviderName:
FPL_IndicationProvider.Error5766
The CC - XBC link failed to initialize. Probable Cause: An XBC is indicating a port
failure. Recommended Action: Validate all of the cells connectivity to the PDCheck
the XBC chips seating reset the system replace either cells/system backplane. WBEM
EventID: 508. WBEM ProviderName: FPL_IndicationProvider.Error5767
Unable to determine system mode because EFI/SAL interface not initialized. Probable
Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If
problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
509. WBEM ProviderName: FPL_IndicationProvider.Warning5768
BMC returned an invalid system mode. Probable Cause: Mismatch between BMC
and EFI firmware. Recommended Action: Upgrade system firmware or BMC firmware
as necessary. If problem persists, contact HP support to troubleshoot the problem.
WBEM EventID: 510. WBEM ProviderName: FPL_IndicationProvider.Warning5769
EFI unable to specify system mode because EFI/SAL interface not initialized. Probable
Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If
problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
511. WBEM ProviderName: FPL_IndicationProvider.Warning5770
Unable to enter normal system mode because EFI/SAL interface not initialized.
Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware.
If problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
512. WBEM ProviderName: FPL_IndicationProvider.Warning5771
Unable to initialize part of the SAL/EFI interface. Probable Cause: Incompatible
versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem
persists contact your HP representative for support. WBEM EventID: 513. WBEM
ProviderName: FPL_IndicationProvider.Error5772
An expected tree node was not found. Probable Cause: This is a bug. Contact
engineering. WBEM EventID: 515. WBEM ProviderName: FPL_IndicationProvider.Error5774
EFI unable to modify system state to 'running'. Probable Cause: BMC malfunctioning.
Recommended Action: Reset BMC. WBEM EventID: 516. WBEM ProviderName:
FPL_IndicationProvider.Warning5776
/options settings for CPUBusConfigValue aren't compatible with PAL. Probable
Cause: Update the /options value to comply with the desired features and what is
supported. WBEM EventID: 2433. WBEM ProviderName: FPL_IndicationProvider.Warning5777
The Get Processor Bus Dependent Configuration Features PAL call failed. Probable
Cause: Contact engineering. There is a PAL compatibility problem. WBEM EventID:
518. WBEM ProviderName: FPL_IndicationProvider.Warning5778
memory DIMM pair mismatch. Probable Cause: The user installed a mismatched
pair of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width).
Recommended Action: Install memory ranks in pairs of DIMMs that are the same
size and DRAM width. WBEM EventID: 519. WBEM ProviderName:
FPL_IndicationProvider.Warning5779
EFI unable to initialize internal library. Probable Cause: Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 520. WBEM ProviderName: FPL_IndicationProvider.Error5784
EFI unable to initialize security system. Probable Cause: BMC not responding
properly. Recommended Action: Reset BMC. Contact your HP representative if
problem persists. WBEM EventID: 521. WBEM ProviderName:
FPL_IndicationProvider.Error5785
36 WBEM Provider Event Tables