HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
Unable to validate blank password during EFI security initialization. Probable Cause:
BMC failed. Recommended Action: Reset the BMC. Update BMC FW. Contact your
HP representative to check the BMC. WBEM EventID: 551. WBEM ProviderName:
FPL_IndicationProvider.Warning5832
Unable to enter Guest mode during EFI security initialization. Probable Cause: BMC
failure. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP
representative to check the BMC. WBEM EventID: 552. WBEM ProviderName:
FPL_IndicationProvider.Warning5833
Unable to increase privilege during EFI security initialization. Probable Cause: BMC
failure. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP
representative concerning the BMC. WBEM EventID: 553. WBEM ProviderName:
FPL_IndicationProvider.Warning5834
EFI unable to write privilege level during security initialization. Probable Cause:
SAL failure. Recommended Action: Reboot the system. Update SFW. If problem
persists, contact HP support to troubleshoot the problem. WBEM EventID: 554.
WBEM ProviderName: FPL_IndicationProvider.Warning5836
EFI was denied permission to write the privilege level during security init. Probable
Cause: SAL is not in ADMIN or USER mode. Recommended Action: Reboot the
system. Upgrade system firmware. If problem persists, contact HP support to
troubleshoot the problem. WBEM EventID: 555. WBEM ProviderName:
FPL_IndicationProvider.Warning5837
OS dump, error writing image area to disk (E055). Probable Cause: panic path forward
progress. WBEM EventID: 556. WBEM ProviderName: FPL_IndicationProvider.Warning5853
Coherency controller (CC) registers indicate a Deadlock Recovery Reset. Probable
Cause: Coherency controller (CC) resources are deadlocked and the CC is resetting
the cell. Recommended Action: Analyze the Deadlock Recovery logs (like MCA logs)
to determine the cause of the failure. WBEM EventID: 1019. WBEM ProviderName:
FPL_IndicationProvider.Error5896
A memory address parity error has been detected. The physical location can be located
in the data field. Probable Cause: Poorly seated memory extender. Recommended
Action: Reseat memory extender. WBEM EventID: 5268. WBEM ProviderName:
FPL_IndicationProvider.Error6002
A DIMM loading order error has occurred. Probable Cause: Incorrect loading of the
DIMMs on the cell. Recommended Action: Install the DIMMs in the correct order.
DIMMs are installed in ranks of DIMMs , starting with DIMM 0A, 0B, etc. Subsequent
ranks are loaded in ascending order , i.e., rank 1, 2, 3, 4, 5, 6 and 7. WBEM EventID:
590. WBEM ProviderName: FPL_IndicationProvider.Error6074
Refresh Control Error Timeout. Probable Cause: At start of memory refresh, timing
out waiting for ready bit to be set. Recommended Action: Contact HP Support
personnel to troubleshoot the problem. WBEM EventID: 591. WBEM ProviderName:
FPL_IndicationProvider.Warning6146
memory extender/baseboard FRU mismatch. Probable Cause: Memory extender and
baseboard are incompatible. Recommended Action: Contact HP support to
troubleshoot the problem. WBEM EventID: 592. WBEM ProviderName:
FPL_IndicationProvider.Warning6180
Fabric topology mismatch with XBCs in complex. Probable Cause: There is a fabric
topology mismatch with XBC in complex. Recommended Action: Contact HP Support
personnel to analyze the cell, XBC flex cables, system backplane. WBEM EventID:
593. WBEM ProviderName: FPL_IndicationProvider.Error6730
An invalid XBC to XBC port was found. Probable Cause: Loss of Lockstep.
Recommended Action: Reset. WBEM EventID: 594. WBEM ProviderName:
FPL_IndicationProvider.Warning6795