HP Insight Management WBEM Provider Events Reference Guide

Power fault on cell board. Probable Cause: One or more of the DC to DC power
converters on the Cell Power Board is displaying a fault condition. Recommended
Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID:
708. WBEM ProviderName: FPL_IndicationProvider.Error7903
The CPU Node reported a problem initializing its node in the device tree. Probable
Cause: See additional logs in determine why initialize node failed. There could be a
hardware or PAL problem. WBEM EventID: 2437. WBEM ProviderName:
FPL_IndicationProvider.Warning7938
The ExecuteCommand function failed on a CPU. Probable Cause:
Inter-Processor-Interrupts may not be working, or the command may have timed
out. This could be a firmware bug or hardware problem. Look for other clues in the
event log. WBEM EventID: 710. WBEM ProviderName: FPL_IndicationProvider.Warning7939
A remote CPU is not prepared to receive a command. Probable Cause: The CPU may
be stuck waiting for a previous command or may not be healthy. This could also be
caused by a system resource contention problem. WBEM EventID: 711. WBEM
ProviderName: FPL_IndicationProvider.Warning7940
An error was encountered when executing a PAL_PROC. Probable Cause: PAL was
unable to be successfully called. See other event ids to determine if action needs to
be taken. WBEM EventID: 614. WBEM ProviderName: FPL_IndicationProvider.Warning7948
CPUs loaded in wrong order. Probable Cause: CPUs not loaded in correct order.
Recommended Action: Load CPUs in order 0, 1, 2, 3. WBEM EventID: 615. WBEM
ProviderName: FPL_IndicationProvider.Error7953
The XBC SBE and LPE errors were not cleared properly. Probable Cause: the link
generated a new error. Recommended Action: check CC, check link Check logs for
other errors. If error is persistent, replace cell board. WBEM EventID: 1031. WBEM
ProviderName: FPL_IndicationProvider.Error7963
The CC to XBC link pattern test failed. Probable Cause: Unspecified. WBEM EventID:
2438. WBEM ProviderName: FPL_IndicationProvider.Error7964
Error Reading a platform storage variable from the PDHC/MP. Probable Cause:
Either the MP is not present, or the requested information does not exist. Ensure that
the MP is functioning and that the proper data is being requested. WBEM EventID:
616. WBEM ProviderName: FPL_IndicationProvider.Error7965
An error was returned on a Platform Storage Write Command to the PDHC/MP.
Probable Cause: The MP is not present, may be out of space, or the command was
badly formatted. Ensure that the MP has enough space and try again. If the problem
persists, contact engineering. WBEM EventID: 617. WBEM ProviderName:
FPL_IndicationProvider.Error7966
The Sequencer was unable to find/use a needed tree node. Probable Cause: This is a
bug, contact engineering. WBEM EventID: 618. WBEM ProviderName:
FPL_IndicationProvider.Error7973
Firmware encountered an error in processing the partition variables. Probable Cause:
Either the GSP was not present or there was a resource problem storing the variable.
There should be other clues in the event id log to indicate which is the case. Restore
the GSP. WBEM EventID: 619. WBEM ProviderName: FPL_IndicationProvider.Error7974
A non-critical cell power fault has occurred. Probable Cause: A CPU Power Module
has been disabled following a thermal warning reported by that CPU Module.
Recommended Action: Contact HP Support personnel to troubleshoot the problem.
WBEM EventID: 620. WBEM ProviderName: FPL_IndicationProvider.Error7975
CPUProcConfigValue in /options is not compatible with the current PAL/CPU.
Probable Cause: Modify CPUProcConfigValue in /options to set the correct bits.
WBEM EventID: 2439. WBEM ProviderName: FPL_IndicationProvider.Error8009
Firmware was unable to determine the Processor Dependent Features. Probable
Cause: Contact Engineering, This is a bug. WBEM EventID: 622. WBEM
ProviderName: FPL_IndicationProvider.Warning8010