HP Insight Management WBEM Provider Events Reference Guide

Data field contains data meant for firmware debug only. Probable Cause: Debug
event. Recommended Action: Contact your hp support representative. WBEM
EventID: 2434. WBEM ProviderName: FPL_IndicationProvider.Error8127
The CLU has encountered an undefined case. Probable Cause: CLU firmware on the
UGUY has gotten into an unexpected execution path, most likely due to a hardware
issue on the UGUY. Recommended Action: Check revision of CLU firmware. If out
of date, or known bad revision, use FWUU to update CLU firmware. Contact HP
Support personnel to troubleshoot problem. WBEM EventID: 624. WBEM
ProviderName: FPL_IndicationProvider.Error8128
An unknown Cell voltage margin has been detected. Probable Cause: A user has
manually, using back-door debugging methods, altered the voltage margin setting
of one or more Cell Board or Cell Power Board converters. WBEM EventID: 625.
WBEM ProviderName: FPL_IndicationProvider.Warning8130
The run-time verification of a programming assumption has failed. Probable Cause:
Hardware or software in unknown state. Recommended Action: Upgrade PDHC
firmware to latest revision. If already at current revision, contact HP Support
personnel to troubleshoot the problem. WBEM EventID: 626. WBEM ProviderName:
FPL_IndicationProvider.Warning8131
An unknown error has been detected by the PDHC firmware. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:.
Recommended Action: Upgrade PDHC firmware to latest revision. If already at
current revision, contact HP support personnel to troubleshoot the problem. WBEM
EventID: 627. WBEM ProviderName: FPL_IndicationProvider.Warning8132
An attempt to write to a device on the PDHCs I2C bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 628. WBEM ProviderName: FPL_IndicationProvider.Warning8133
An attempt to read from a device on the PDHC's I2C bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 629. WBEM ProviderName: FPL_IndicationProvider.Warning8134
An attempt to write to a device on the PDHC's SM bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. WBEM
EventID: 630. WBEM ProviderName: FPL_IndicationProvider.Warning8135
An attempt to read from a device on the PDHC's SM bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and PDH Daughtercard. WBEM
EventID: 631. WBEM ProviderName: FPL_IndicationProvider.Warning8136
Cell boot has been disabled due to a failure setting the frequency registers. Probable
Cause: A hardware fault has occurred. Recommended Action: Contact HP Support
personnel to troubleshoot the problem. WBEM EventID: 632. WBEM ProviderName:
FPL_IndicationProvider.Error8137
An error has occurred while updating System FW. Probable Cause: Obsolete version
of FWUU. Recommended Action: If you are not using the latest revision of FWUU,
obtain and use the latest version of FWUU to retry the update. WBEM EventID: 633.
WBEM ProviderName: FPL_IndicationProvider.Warning8138
The PDHC firmware was reset for some unknown reason. Probable Cause: An
unknown hardware fault has caused the PDHC to reset. Recommended Action:
Upgrade PDHC firmware to the latest revision. If the error continues, contact HP
support personnel to troubleshoot the PDH Daughtercard and/or Cell Board. WBEM
EventID: 634. WBEM ProviderName: FPL_IndicationProvider.Warning8139
Cell boot has been disabled because setup of a CPU thermal sensor failed. Probable
Cause: A hardware fault prevents access to a CPU module's Processor Information
ROM. Recommended Action: Contact HP support personnel to troubleshoot the Cell
Board, the PDH Daughtercard, and/or the offending CPU module. WBEM EventID:
635. WBEM ProviderName: FPL_IndicationProvider.Error8140
48 WBEM Provider Event Tables