HP Insight Management WBEM Provider Events Reference Guide

A CPU module has reported overtemp, so will be powered off in 1 minute. Probable
Cause: The Processor Information ROM on the processor module is unprogrammed
or programmed with invalid temperature thresholds. Recommended Action: Contact
HP support personnel to troubleshoot the problem. WBEM EventID: 636. WBEM
ProviderName: FPL_IndicationProvider.Error8141
An error occurred while updating the PDHC firmware. Probable Cause: MP firmware
not at a revision that supports that version of PDHC firmware. Recommended Action:
If MP is not at a compatible revision, update the MP firmware to a compatible revision
and repeat PDHC firmware update. WBEM EventID: 637. WBEM ProviderName:
FPL_IndicationProvider.Warning8143
Boot is disabled because the cell type does not match the System FW ROM type.
Probable Cause: The System FW ROM in unprogrammed, or an invalid System FW
ROM image is programmed in the System FW flash. Recommended Action: Update
the System FW using Firmware Update from the MP. WBEM EventID: 712. WBEM
ProviderName: FPL_IndicationProvider.Error8147
The PDHC has waited an abnormally long time for PDH bus access. Probable Cause:
A hardware fault is preventing the PDH arbiter from granting the PDHC control of
the bus. Recommended Action: Contact HP support personnel to troubleshoot the
cell board and/or PDH daughtercard. WBEM EventID: 713. WBEM ProviderName:
FPL_IndicationProvider.Warning8149
The PDHC has waited an abnormally long time to obtain the PDH semaphore.
Probable Cause: A hardware fault is preventing the PDH bus semaphore from being
taken/released as expected. Recommended Action: Contact HP support personnel
to troubleshoot the Cell Board and/or PDH Daughtercard. WBEM EventID: 714.
WBEM ProviderName: FPL_IndicationProvider.Warning8151
An error occurred while transmitting an IPMI message in the BMC2HOST direction.
Probable Cause: A hardware fault is preventing the BMC2HOST queue from working.
Recommended Action: Contact HP support personnel to troubleshoot the PDH
Daughtercard. WBEM EventID: 715. WBEM ProviderName: FPL_IndicationProvider.Warning8153
EFI unable to read initial debug level from the BMC. Probable Cause: BMC not
functioning properly. Recommended Action: Reset the BMC. Contact your HP
representative to check the BMC. WBEM EventID: 716. WBEM ProviderName:
FPL_IndicationProvider.Warning8154
A XBC port was unexpectedly found to not be landmined. Probable Cause: An XBC
is indicating a port failure. Recommended Action: Validate all of the cells connectivity
to the PD Check the XBC chips seating reset the system replace either cells/system
backplane. WBEM EventID: 717. WBEM ProviderName: FPL_IndicationProvider.Error8156
An invalid number of XBC ports were landmined in the system. Probable Cause:
Hardware failure: link, crossbar chip, or cell. Recommended Action: Check for
hardware failures. Reset backplane to re-initialize fabric. WBEM EventID: 1033.
WBEM ProviderName: FPL_IndicationProvider.Error8159
The run-time verification of a programming assumption has failed. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:
Upgrade PM firmware to latest revision. If already at current revision, replace UGUY
board. WBEM EventID: 728. WBEM ProviderName: FPL_IndicationProvider.Warning8199
An unknown error has been detected by the PDHC firmware. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:
Upgrade PM firmware to latest revision. If already at current revision, replace UGUY
board. WBEM EventID: 729. WBEM ProviderName: FPL_IndicationProvider.Warning8200
Data field contains data meant for firmware debug only. Probable Cause: Debug
event. Recommended Action: Contact your hp support representative. WBEM
EventID: 2440. WBEM ProviderName: FPL_IndicationProvider.Error8202
A cabinet has been configured using an invalid cabinet number. Probable Cause:
Re-configure cabinet to use a valid cabinet number. WBEM EventID: 732. WBEM
ProviderName: FPL_IndicationProvider.Error8206
Platform Events 49