HP Insight Management WBEM Provider Events Reference Guide

An error was encountered initializing the PCI bridge. Probable Cause: The PCI
component could not initialize a P2P bridge registers, probably due to faulty
hardware. Recommended Action: Reseat or replace the PCI bridge card. WBEM
EventID: 776. WBEM ProviderName: FPL_IndicationProvider.Warning8692
An error was encountered initializing the PCI IO map. Probable Cause: The PCI
component had insufficient IO port space resources to support the installed PCI
cards. Recommended Action: Remove one or more PCI cards to reduce resource
requirements; check for faulty cards that are requesting more resources than they
need. WBEM EventID: 777. WBEM ProviderName: FPL_IndicationProvider.Warning8693
An error was encountered creating the PCI MMIO map. Probable Cause: The PCI
component had insufficient MMIO space to support the installed cards. Recommended
Action: Remove one or more PCI cards to reduce the MMIO requirements; check for
a PCI card requesting more MMIO resources than it needs. WBEM EventID: 778.
WBEM ProviderName: FPL_IndicationProvider.Warning8694
There was an error initializing the SBA node. Probable Cause: An error was while
initializing the SBA firmware structures. Recommended Action: Correct any previous
errors Invalidate NVM and reset replace the cell board. WBEM EventID: 779. WBEM
ProviderName: FPL_IndicationProvider.Error8709
There was an error discovering the SBA. Probable Cause: An error was discovered
with the SBA during discovery. Recommended Action: Correct any previous errors
Replace the I/O backplane. WBEM EventID: 780. WBEM ProviderName:
FPL_IndicationProvider.Error8710
An error was encountered while resetting the SBA. Probable Cause: The SBA
component could not reset one or more LBA ropes, probably due to faulty hardware.
Recommended Action: Replace the failed IO backplane. WBEM EventID: 781. WBEM
ProviderName: FPL_IndicationProvider.Error8711
There was an error initializing the IO link. Probable Cause: The SBA IO link could
not be initialized, probably due to cable installation errors or faulty hardware.
Recommended Action: Re-install or replace the cables; replace the IO backplane.
WBEM EventID: 782. WBEM ProviderName: FPL_IndicationProvider.Warning8712
There is a problem initializing the REO cable. Probable Cause: An SBA IO cable error
has been detected. Recommended Action: Verify proper cable connection,
repair/replace the cables. WBEM EventID: 783. WBEM ProviderName:
FPL_IndicationProvider.Warning8713
The IO chassis discovered was powered off. Probable Cause: Connected IO chassis
is powered off. Recommended Action: Either power on the IO chassis or ignore the
error if it is powered off by design. WBEM EventID: 784. WBEM ProviderName:
FPL_IndicationProvider.Error8714
There was an error initializing the LBA. Probable Cause: The LBA component
initialization routine failed. Recommended Action: This is an internal system firmware
error. Update system firmware or contact a system firmware representative. WBEM
EventID: 785. WBEM ProviderName: FPL_IndicationProvider.Warning8715
There was an error querying the LBA width. Probable Cause: Error while writing
the LBA phase data. Recommended Action: Replace the I/O backplane. WBEM
EventID: 786. WBEM ProviderName: FPL_IndicationProvider.Error8716
There was an error with the LBA phase. Probable Cause: Error while writing the LBA
phase data. Recommended Action: Replace the I/O backplane. WBEM EventID: 787.
WBEM ProviderName: FPL_IndicationProvider.Warning8717
There was an error clearing the LBA. Probable Cause: Unable to clear an error in the
LBA. Recommended Action: Check other events for the error being generated replace
either the PCI card or the I/O backplane. WBEM EventID: 788. WBEM ProviderName:
FPL_IndicationProvider.Warning8718
There was an error with the LBA log. Probable Cause: The LBA component could
not generate error logs. Recommended Action: This is an internal system firmware
error. Update system firmware or contact a system firmware representative. WBEM
EventID: 789. WBEM ProviderName: FPL_IndicationProvider.Error8719
Platform Events 51