HP Insight Management WBEM Provider Events Reference Guide

There was an error discovering the LBA. Probable Cause: The wrong backplane type
was detected. Recommended Action: replace I/O backplane. WBEM EventID: 790.
WBEM ProviderName: FPL_IndicationProvider.Error8720
There was an error configuring the LBA. Probable Cause: Unable to configure the
LBA. Recommended Action: replace I/O backplane. WBEM EventID: 791. WBEM
ProviderName: FPL_IndicationProvider.Warning8721
There was an error scanning the PCI bus. Probable Cause: Could not scan the card
in a populated slot. Typically caused by an improperly installed or faulty PCI card.
Recommended Action: Reseat or replace the faulty card. WBEM EventID: 792. WBEM
ProviderName: FPL_IndicationProvider.Error8722
There was an error configuring PCI space through the LBA. Probable Cause: Unable
to obtain semaphore. Recommended Action: reset Update to latest recipe. WBEM
EventID: 793. WBEM ProviderName: FPL_IndicationProvider.Error8723
Firmware was unable to find a suitable block of main memory to relocate ROM.
Probable Cause: Probably caused by lots of PDT entries, or no main memory present.
WBEM EventID: 1036. WBEM ProviderName: FPL_IndicationProvider.Error8747
The Options service received an NVRAM allocation error. Probable Cause: Invalidate
NVRAM and reset. WBEM EventID: 808. WBEM ProviderName:
FPL_IndicationProvider.Error8756
SAL errlog access timeout. Probable Cause: Firmware is taking too long to process
requests. WBEM EventID: 810. WBEM ProviderName: FPL_IndicationProvider.Warning8758
The echelon given in the data field is not fully populated. Probable Cause: the specified
echelon is not fully populated and is not usable. Recommended Action: add or replace
dimms in the specified echelon. WBEM EventID: 816. WBEM ProviderName:
FPL_IndicationProvider.Warning8768
The main backplane is reporting the LPM status as fault. Probable Cause: Many
possible causes, repair / replace the appropriate part. WBEM EventID: 1760. WBEM
ProviderName: FPL_IndicationProvider.Warning8784
The IO backplane is reporting a LPM status as fault. Probable Cause: Service / replace
the appropriate part of, or the entire backplane. WBEM EventID: 1762. WBEM
ProviderName: FPL_IndicationProvider.Warning8787
System firmware was unable to default the complex profile. Probable Cause: Needed
information could not be obtained. Reset the MP. WBEM EventID: 822. WBEM
ProviderName: FPL_IndicationProvider.Error8797
Firmware could not set Pal Proc features. Probable Cause: FW MCA code uses this
PAL_SET_PROC_FEATURES to escalate future MCA to BINIT. This event id when
emitted during an MCA processing means that any subsequent global MCA would
not cause all the processors in the PD to MCA again. WBEM EventID: 2443. WBEM
ProviderName: FPL_IndicationProvider.Warning8798
Means that the error log space in the Nvram has not been allocated. Probable Cause:
This happens because of the NVRAM is full with unconsumed error logs. Clear the
error logs. WBEM EventID: 824. WBEM ProviderName: FPL_IndicationProvider.Warning8806
This indicates the maximum number of logs for the event. Probable Cause: This
shouldn't be occur. But in case it does than clear the error logs of this event type from
the nvram. WBEM EventID: 825. WBEM ProviderName: FPL_IndicationProvider.Warning8807
On Line Delete operation was begun but firmware couldn't find a deleteable cell.
Probable Cause: This can occur if the OS has not returned all the CPUs to firmware
or if a cell is not marked correctly in the complex profile to allow its deletion. WBEM
EventID: 826. WBEM ProviderName: FPL_IndicationProvider.Warning8814
The bulk power system is above its current capacity. Probable Cause: N/A. WBEM
EventID: 827. WBEM ProviderName: FPL_IndicationProvider.Error8817
The bulk specified is warning of a potential thermal problem. Probable Cause: The
bulk power supply is warning of an over temperature condition. WBEM EventID:
828. WBEM ProviderName: FPL_IndicationProvider.Warning8818