HP Insight Management WBEM Provider Events Reference Guide

Invalid data read from a CPU module's Processor Information ROM. Probable Cause:
The CPU module's Processor Information ROM is unprogrammed. Recommended
Action: Contact HP support personnel to troubleshoot the CPU module pointed to
by the physical location portion of this event. WBEM EventID: 849. WBEM
ProviderName: FPL_IndicationProvider.Warning8877
Invalid parameter when setting cpu frequency ratios. Probable Cause: Specify a valid
parameter. WBEM EventID: 2444. WBEM ProviderName: FPL_IndicationProvider.Warning8882
Option block in nvram has a checksum error. Probable Cause: Clear NVRAM. WBEM
EventID: 851. WBEM ProviderName: FPL_IndicationProvider.Warning8883
An Error occurred trying to notify the MP of the attempted reset. Probable Cause:
The MP is not functioning or the PDHC cannot communicate with it. Reset the MP.
WBEM EventID: 858. WBEM ProviderName: FPL_IndicationProvider.Warning8906
Cell has been disabled by the PDHC because no CPU modules were found. Probable
Cause: The CPU module(s) that are installed have invalid data stored in the partition
specific field of the FRU EEPROM. Recommended Action: If in manufacturing,
reprogram the partition specific field of the CPU module(s) FRU EEPROM. Otherwise,
contact HP support personnel to troubleshoot the unreported CPU module. WBEM
EventID: 866. WBEM ProviderName: FPL_IndicationProvider.Error8940
Cell has been disabled by PDHC FW because the CPU modules are not compatible.
Probable Cause: At least one of the installed CPU modules are incompatible with at
least one other CPU module. Recommended Action: Contact HP support personnel
to troubleshoot the CPU modules on the Cell. WBEM EventID: 867. WBEM
ProviderName: FPL_IndicationProvider.Error8941
Cell has been disabled because of invalid data in a CPU module Scratch EEPROM.
Probable Cause: The CPU module is not an HP CPU module, or the FRUID data for
this CPU module has not been programmed. Recommended Action: Contact HP
support personnel to troubleshoot the CPU module. WBEM EventID: 868. WBEM
ProviderName: FPL_IndicationProvider.Error8942
The Cell Battery voltage level low warning. Probable Cause: The Cell Battery is low.
Recommended Action: It needed to be replaced. WBEM EventID: 869. WBEM
ProviderName: FPL_IndicationProvider.Warning8954
The CPU is performance or functionally restricted. Probable Cause: A CPU is broken.
Replace it. WBEM EventID: 885. WBEM ProviderName: FPL_IndicationProvider.Warning8979
The RTC was found to be invalid and has been cleared. Probable Cause: The RTC
was invalid. Recommended Action: No action is required. The problem has been
corrected by SFW. WBEM EventID: 886. WBEM ProviderName:
FPL_IndicationProvider.Warning8981
Status indicates that the Late Self Tests did not actually run. Probable Cause: This
could be caused by an incompatibility problem between PAL and the CPUs. Check
that PAL supports all the CPUs installed on the system. WBEM EventID: 887. WBEM
ProviderName: FPL_IndicationProvider.Warning8982
DRAM failure on DIMM XX, deallocate rank. Probable Cause: SFW detected a failing
DIMM. Recommended Action: Replace the DIMM flagged by SFW. WBEM EventID:
890. WBEM ProviderName: FPL_IndicationProvider.Warning9000
System Clocks are not valid. Probable Cause: The Cell board has a problem. Either
the Real Time Clock is not working properly or the system is not being clocked at
the value it thinks it is. WBEM EventID: 891. WBEM ProviderName:
FPL_IndicationProvider.Error9019
A reset for reconfiguration will be performed soon on the cell. Probable Cause: An
error during cell initialization occurred and the cell will not be able to join the
partition. Look for other errors in the event log that articulate the exact problem.
WBEM EventID: 900. WBEM ProviderName: FPL_IndicationProvider.Warning9043
The Partition Profile specifies the wrong architecture type. Probable Cause: This is
caused by the wrong type of complex profile being loaded. System firmware will
default a new partition profile and continue on. WBEM EventID: 901. WBEM
ProviderName: FPL_IndicationProvider.Warning9045
54 WBEM Provider Event Tables