HP Insight Management WBEM Provider Events Reference Guide

PDHC has detected the PDH battery low warning. Probable Cause: PDH battery
power is low. Recommended Action: Replaced the PDH battery. WBEM EventID:
1037. WBEM ProviderName: FPL_IndicationProvider.Warning9438
FW will not handoff to the OS_MCA handler for this MCA event. Probable Cause:
The error logs should be retrieved from the EFI shell prompt. WBEM EventID: 941.
WBEM ProviderName: FPL_IndicationProvider.Error9440
The NVRAM block table maintained by System Firmware is corrupt. Probable Cause:
The NVRAM-based descriptor for System Firmware NVRAM blocks is corrupt.
WBEM EventID: 942. WBEM ProviderName: FPL_IndicationProvider.Error9448
The link between the CC and SBA failed. Probable Cause: See other associated events
for the root cause of the failure. WBEM EventID: 961. WBEM ProviderName:
FPL_IndicationProvider.Error9484
The SBA failed and the cell has no I/O. Probable Cause: Cannot configure IO on the
cell, probably due to previous errors. Recommended Action: Correct the
hardware/software problem indicated by previous errors. WBEM EventID: 962.
WBEM ProviderName: FPL_IndicationProvider.Error9485
The system firmware had an error with the structured error handling mechanism.
Probable Cause: Either there is an error in the system firmware or the system firmware
has exhausted all resources. Recommended Action: Invalidate NVM or check for
newer version of system firmware. WBEM EventID: 963. WBEM ProviderName:
FPL_IndicationProvider.Error9486
Not enough malloc resources for I/O structure error handling. Probable Cause: Either
invalidate NVM or check for a new version of system firmware. WBEM EventID:
964. WBEM ProviderName: FPL_IndicationProvider.Error9487
Unable to create entry for I/O structure error handling. Probable Cause: This is a
system firmware error, either invalidate NVM or check for a newer version of system
firmware. WBEM EventID: 965. WBEM ProviderName: FPL_IndicationProvider.Error9488
Unable to bind services for I/O structure exception handling. Probable Cause: This
is a system firmware error. Either reset NVM or check for a newer version of system
firmware. WBEM EventID: 966. WBEM ProviderName: FPL_IndicationProvider.Error9489
Error initializing the I/O structure exception handling services. Probable Cause: This
is a system firmware error. Either reset NVM or check for a newer version of system
firmware. WBEM EventID: 967. WBEM ProviderName: FPL_IndicationProvider.Error9490
Error initializing structured I/O exception data structures. Probable Cause: This is a
system firmware error, there is a conflict with system resources. Either reset NVM
or check for a newer version of system firmware. WBEM EventID: 968. WBEM
ProviderName: FPL_IndicationProvider.Error9491
The I/O exception context has an error. Probable Cause: This is a system firmware
error. Reset the system, invalidate NVM and reset the system, or check for a newer
version of the system firmware. WBEM EventID: 969. WBEM ProviderName:
FPL_IndicationProvider.Error9492
Error creating the internal data and services for the SBA. Probable Cause: This is a
system firmware error. Reset the system; invalidate NVM and reset the system; or
check for a newer version of system firmware. WBEM EventID: 970. WBEM
ProviderName: FPL_IndicationProvider.Error9493
Error attaching the services to the SBA internal data structures. Probable Cause: This
is a system firmware error. Reset the partition; invalidate NVM on the reporting cell
and reset the system; or check for a newer version of system firmware. WBEM
EventID: 971. WBEM ProviderName: FPL_IndicationProvider.Error9494
Error initializing the internal SBA data and services. Probable Cause: This is a system
firmware error. Reset the partition; invalidate NVM on the reporting cell and reset
the partition; or check for newer system firmware. WBEM EventID: 972. WBEM
ProviderName: FPL_IndicationProvider.Error9495