HP Insight Management WBEM Provider Events Reference Guide

The SBA type is unknown to the system firmware. Probable Cause: This is either a
system firmware error, or the wrong I/O is connected to the system. Validate the
system recipe both firmware and hardware. WBEM EventID: 973. WBEM
ProviderName: FPL_IndicationProvider.Error9496
An embedded I/O device is missing. Probable Cause: Replaces the I/O card specified
by the physical location. WBEM EventID: 974. WBEM ProviderName:
FPL_IndicationProvider.Warning9497
Predictive Failure in Memory. Probable Cause: You will receive this message if the
memory system is observing a lot of corrected ECC errors from a DIMM. The specified
DIMM may need to be serviced. Recommended Action: Contact your HP support
representative to check the affected hardware. WBEM EventID: 1805. WBEM
ProviderName: FPL_IndicationProvider.Warning9652
Windows: Server Agents Management data not accessible, locked property. Probable
Cause: The installed management software has detected an unstable state of the
underlying IPMI (Intelligent Platform Management Interface) subsystem and has
disabled all management information from being shown by any manageability
applications. The management information will become available automatically as
soon as the IPMI subsystem has stabilized. Recommended Action: No action is
required. WBEM EventID: 1806. WBEM ProviderName: FPL_IndicationProvider.Warning9653
PCI slot exceeds power limit. Probable Cause: The I/O configuration's power
consumption exceeds the supported limit. Recommended Action: Remove the I/O
card from each slot indicated by an IO_PCI_POWER_OVERLOAD_ERR event. WBEM
EventID: 976. WBEM ProviderName: FPL_IndicationProvider.Error9658
The clock ratio reported by manageability does not match the actual clock ratio.
Probable Cause: This is a hardware error and it is fatal. WBEM EventID: 2687. WBEM
ProviderName: FPL_IndicationProvider.Error9678
Manual override of fatal stop boot condition. Probable Cause: The user has initiated
manual O/S boot despite the existence of a error. Recommended Action: Correct the
error condition (see output of 'INFO WARNING' EFI shell command), reboot the
system, and then initiate O/S boot. WBEM EventID: 985. WBEM ProviderName:
FPL_IndicationProvider.Error9681
Firmware unable to relocate VGA BIOS. Probable Cause: Most likely there is a
permanent memory error in the VGA BIOS region (physical address 0xc0000 - 0xdffff).
Recommended Action: Replace the DIMM causing the permanent memory error in
the VGA BIOS region. The PDT reports which DIMM is causing errors in the physical
address range 0xc0000 - 0xdffff. WBEM EventID: 986. WBEM ProviderName:
FPL_IndicationProvider.Warning9682
The Compatibility Matrix stored in NVRAM has a checksum error. Probable Cause:
NVRAM has become corrupt. Restore from a backup. WBEM EventID: 987. WBEM
ProviderName: FPL_IndicationProvider.Error9685
The buffer size is too small for the XBC error log. Probable Cause: Firmware error.
Recommended Action: Reset cell. WBEM EventID: 1002. WBEM ProviderName:
FPL_IndicationProvider.Error9740
System firmware was unable to clear an XBC error. Probable Cause: The particular
XBC and port could have a persistent error. Recommended Action: Check flex cable
indicated by event data. WBEM EventID: 1003. WBEM ProviderName:
FPL_IndicationProvider.Error9741
Error encountered while collecting PCI error logs. Probable Cause: An error occurred
while collecting the PCI error logs. Recommended Action: No action can be taken.
The result is some or all PCI error logs will be unavailable. WBEM EventID: 2446.
WBEM ProviderName: FPL_IndicationProvider.Error9744
Error encountered while collecting SBA error logs. Probable Cause: An error occurred
while collecting the SBA error logs. Recommended Action: No action can be taken.
The result is some or all SBA error logs will be unavailable. WBEM EventID: 2447.
WBEM ProviderName: FPL_IndicationProvider.Error9745
Platform Events 57