HP Insight Management WBEM Provider Events Reference Guide

Fabric is unable to route the crossbar after multiple retry attempts. Probable Cause:
Hardware problem. Possible bad XBC or Cell Controller. Recommended Action:
Check for hardware failures. Reset backplane to re-initialize fabric. WBEM EventID:
1005. WBEM ProviderName: FPL_IndicationProvider.Error9746
Windows: Predictive Failure in Memory (Warning). Probable Cause: You will receive
this message if the system is correcting a lot of ECC single bit errors. It may mean
that the module is about to fail, or environmental conditions in the server are causing
more errors than usual. This event message will be generated for one of the following
conditions 1000 single-bit errors on the same address in a 48 hour time period. 50
single-bit errors on the same DIMM (not the same address) in a 24 hour time period.
100 single-bit errors on the same DIMM (not the same address) in a 1 week time
period. Recommended Action: If you receive this message, contact your support
provider to determine if a predictive repair should be made. WBEM EventID: 1820.
WBEM ProviderName: FPL_IndicationProvider.Warning9750
Windows: Predictive Failure in Memory (Critical). Probable Cause: You will receive
this message if the system is correcting a lot of ECC single bit errors. It may mean
that the module is about to fail, or environmental conditions in the server are causing
more errors than usual. This event message will be generated for one of the following
conditions 1500 single-bit errors on the same address in a 72 hour time period. 120
single-bit errors on the same DIMM (not the same address) in a 24 hour time period.
130 single-bit errors on the same DIMM (not the same address) in a 1 week time
period. Recommended Action: If you receive this message, contact your support
provider to determine if a predictive repair should be made. WBEM EventID: 1821.
WBEM ProviderName: FPL_IndicationProvider.Error9751
A rope parity error occurred. Probable Cause: An unexpected but random error
occurred. Reboot the system. There is a problem with the system bus. Contact your
HP representative to check the system bus. WBEM EventID: 1822. WBEM
ProviderName: FPL_IndicationProvider.Error9753
PCI card inaccessible due to bus error. Probable Cause: There is a problem with the
system bus. Contact your HP representative to check for faulty devices on the bus..
WBEM EventID: 1823. WBEM ProviderName: FPL_IndicationProvider.Error9754
PCI card inaccessible due to device error. Probable Cause: An unexpected but random
error occurred. Reboot the system. There is a problem with the system bus. Contact
your HP representative to check the system bus. Check the system forward progress
log (available from the Management Processor) for additional information about this
problem. WBEM EventID: 1824. WBEM ProviderName: FPL_IndicationProvider.Error9755
error reading bmc first boot token. Probable Cause: FW tried to read the first boot
token and received a failure. Recommended Action: AC power cycle the system . If
this doesn't work, contact HP support. WBEM EventID: 1825. WBEM ProviderName:
FPL_IndicationProvider.Error9768
An error occurred while enabling hashing in the platform cache. Probable Cause: An
error return status. This could happen if the tree was corrupted or there was an error
verifying the hashing setting. Recommended Action: reset the partition. WBEM
EventID: 1842. WBEM ProviderName: FPL_IndicationProvider.Error9801
It indicates loss of cell connectivity in the partition. Probable Cause: It will lead to
cells performing RESET_FOR_RECONFIG after getting the error logs. WBEM EventID:
2448. WBEM ProviderName: FPL_IndicationProvider.Error9832
Error building cell-level FW device tree. Probable Cause: Data field displays the
status of creating the cell level device tree for use by firmware. See previous errors
already reported. WBEM EventID: 2450. WBEM ProviderName:
FPL_IndicationProvider.Error9849
The NVRAM service was unable to satisfy an NVRAM allocation request. Probable
Cause: NVRAM is full. This is extremely unlikely. Recommended Action: Clear
NVRAM and reset. WBEM EventID: 2499. WBEM ProviderName:
FPL_IndicationProvider.Error10116
58 WBEM Provider Event Tables