HP Insight Management WBEM Provider Events Reference Guide

The OS has registered an OS_INIT vector, but it has not passed the checksum. Probable
Cause: The OS has registered an OS_INIT vector and checksum, but the checksum
did not match the calculated value. Recommended Action: Reboot. If problem persists,
contact support. WBEM EventID: 8339. WBEM ProviderName:
FPL_IndicationProvider.Warning10117
The RTC not updating its internal time registers. Probable Cause: Bad RTC chip on
the PDH daughtercard. Recommended Action: Replace PDH daughtercard. WBEM
EventID: 2512. WBEM ProviderName: FPL_IndicationProvider.Error10132
Uncorrectable PAA fault on MX2. Probable Cause: An uncorrectable PAA fault has
occurred on the MX2 module and PAA firmware has halted. Recommended Action:
Contact your HP support personnel. WBEM EventID: 2740. WBEM ProviderName:
FPL_IndicationProvider.Warning10159
fabric API is about to open the a link going out of the local cell. Probable Cause: An
error prevented the use of a fabric link. Recommended Action: Collect IPMI event
logs for more information regarding the failure. Contact your HP Support
Representative to investigate the fabric subsystem. WBEM EventID: 2914. WBEM
ProviderName: FPL_IndicationProvider.Warning10209
One or more of the blades in the domain could not communicate. Probable Cause:
Connection problem between blade and the enclosure. Recommended Action: iLO
will attempt to correct communication issues. If this fails verify FW is at a supported
revision and matached across the blades. Consider cycling stby power to the affected
blades. WBEM EventID: 8083. WBEM ProviderName: FPL_IndicationProvider.Error10213
An Arches fabric CSR read was unsuccessful because of a timeout. Probable Cause:
An error occurred while reading a hardware register. Other events should detail the
error. Recommended Action: Contact your HP Support Representative to investigate
the fabric and firmware vertex modules. WBEM EventID: 2908. WBEM ProviderName:
FPL_IndicationProvider.Error10272
An Arches fabric CSR write was unsuccessful. Probable Cause: An error occurred
while writing a hardware register. Other events should detail the error. Recommended
Action: Contact your HP Support Representative to investigate the fabric and firmware
vertex modules. WBEM EventID: 2909. WBEM ProviderName:
FPL_IndicationProvider.Error10273
The event data details the error that was encountered. Probable Cause: A fabric error
occurred while preparing for rendezvous. Recommended Action: Contact your HP
Support Representative to investigate the fabric and firmware vertex modules. WBEM
EventID: 2910. WBEM ProviderName: FPL_IndicationProvider.Error10343
The maximum memory supported by this system has been exceeded. Probable Cause:
Too much memory has been installed in the system. Recommended Action: Remove
DIMMs to get the total memory size below the amount of memory returned in the
data field. WBEM EventID: 2911. WBEM ProviderName: FPL_IndicationProvider.Error10351
Failed to delete a bad port while routing the fabric. Data field indicates return status.
Probable Cause: Experienced an error while routing the fabric. Recommended Action:
Contact your HP Support Representative to investigate the fabric and firmware vertex
modules. WBEM EventID: 4848. WBEM ProviderName: FPL_IndicationProvider.Warning10357
Failed to delete an edge that was found to be bad during routing. Probable Cause:
Experienced an error while routing the fabric. Recommended Action: Contact your
HP Support Representative to investigate the fabric and firmware vertex modules.
WBEM EventID: 4849. WBEM ProviderName: FPL_IndicationProvider.Warning10358
A command to the memory buffer chip failed to complete. Probable Cause: System
firmware did not get a completion status from a command to a memory buffer chip.
Recommended Action: Contact HP support. WBEM EventID: 2917. WBEM
ProviderName: FPL_IndicationProvider.Error10361