HP Insight Management WBEM Provider Events Reference Guide

The Arches Fabric function ArfIsCsrRouteTraversable was called for a back-to-back
system. This is unsupported, ArfIsCsrRouteTraversable should only be called for
systems with crossbars. No data. Probable Cause: An unsupported fabric call was
made. Recommended Action: Contact your HP Support Representative to investigate
the fabric and firmware vertex modules. WBEM EventID: 2918. WBEM ProviderName:
FPL_IndicationProvider.Warning10375
An invalid port number was given as an input to an Arches Fabric Traversability
function. The port is expected to be an internal XBC num (8-15), but the actual port
was not. Data field: (XBC number 32) | (port number 48). Probable Cause: Internal
firmware error. Recommended Action: Contact your HP Support Representative to
investigate the fabric and firmware vertex modules. WBEM EventID: 2919. WBEM
ProviderName: FPL_IndicationProvider.Warning10376
Unable to read XBC port neighbor information. Data field: (xbcNum 32) | (portNum
48). Probable Cause: System firmware was unable to read a fabric hardware register.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2920. WBEM
ProviderName: FPL_IndicationProvider.Warning10377
XBC port with an unexpected neighbor chip type. Data field: (expected chip type) |
(actual chip type 16) | (xbcNum 32) |(portNum 48). Probable Cause: System firmware
noticed a discrepancy from the expected topology of the system. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 2921. WBEM ProviderName:
FPL_IndicationProvider.Warning10378
An XBC port was found to have an unexpected neighbor ID. Data field: (expected
NID) | (actual NID 16) | (xbcNum 32) | (portNum 48). Probable Cause: System
firmware found a discrepancy in the expected topology of the system. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 2922. WBEM ProviderName:
FPL_IndicationProvider.Warning10379
An XBC was found to have an unexpected neighbor port connection. Data field:
(expected port) | (actual port 16) | (xbcNum 32) | (portNum 48). Probable Cause:
System firmware found a discrepancy in the expected topology of the system.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2923. WBEM
ProviderName: FPL_IndicationProvider.Warning10380
The expected data was not found in the Arches Fabric expected edge list. Data field
is unused. Probable Cause: Internal system firmware error or data corruption.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2924. WBEM
ProviderName: FPL_IndicationProvider.Warning10381
An XBC port has an unexpected neighbor chip type. Data field: neighbor type found.
Probable Cause: System firmware found an unexpected chip in the system.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2925. WBEM
ProviderName: FPL_IndicationProvider.Warning10382
A previously good XBC-XBC link was found to be down. Data field: (xbcNum 32) |
(portNum 48). Probable Cause: A link that was previously healthy was found to be
down. Recommended Action: Capture IPMI event logs, look for additional errors.
Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2926.
WBEM ProviderName: FPL_IndicationProvider.Warning10384
An XBC port was found to have a Fatal Error during traversability test. Data field:
(xbcNum 32) | (portNum 48). Probable Cause: A link was found to have fatal errors,
possible bad link/connection. Recommended Action: Capture IPMI event logs, look
for additional errors. Contact your HP Support Representative to analyze the fabric.
WBEM EventID: 2927. WBEM ProviderName: FPL_IndicationProvider.Warning10385
60 WBEM Provider Event Tables