HP Insight Management WBEM Provider Events Reference Guide

Error reading ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32)
| (portNum 48). Probable Cause: System firmware was unable to read a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
2939. WBEM ProviderName: FPL_IndicationProvider.Warning10397
An XBC port was found with an unexpected neighbor chip. Data field: expected chip
type | (actual chip type 32). Probable Cause: System firmware found a discrepancy
in the expected system topology. Recommended Action: Capture IPMI event logs,
look for additional errors. Contact your HP Support Representative to analyze the
fabric. WBEM EventID: 2940. WBEM ProviderName: FPL_IndicationProvider.Warning10398
A cell/port pair was not found in the expected graph data. Data field: (cellNum 32)
| CC portNum. Probable Cause: Internal firmware error or data corruption.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2942. WBEM
ProviderName: FPL_IndicationProvider.Warning10401
Arches Fabric Traversability code unexpectedly found the local cell link not connected.
Data field: linkState (0 = connected, 1 = link pending, 2 = not connected, -1 = error).
Probable Cause: A previously healthy link was found to have fatal errors.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2943. WBEM
ProviderName: FPL_IndicationProvider.Warning10402
Error reading the ROUTEx CSR on the XBC. Data field: route index | (xbcNum 32)
| (portNum 48). Probable Cause: System firmware was unable to read a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
2944. WBEM ProviderName: FPL_IndicationProvider.Warning10403
Unable to read the ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum
32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
2945. WBEM ProviderName: FPL_IndicationProvider.Warning10404
An XBC port has an unexpected neighbor chip type. Data field: expected neighbor
chip type | (actual neighbor chip type 32). Probable Cause: System firmware found
a discrepancy in the expected system topology. Recommended Action: Capture IPMI
event logs, look for additional errors. Contact your HP Support Representative to
analyze the fabric. WBEM EventID: 2946. WBEM ProviderName:
FPL_IndicationProvider.Warning10405
A Cell-Cell link has an unexpected neighbor chip type. Data field: expected neighbor
chip type | (actual neighbor chip type 32). Probable Cause: System firmware has
found a discrepancy in the expected system topology. Recommended Action: Capture
IPMI event logs, look for additional errors. Contact your HP Support Representative
to analyze the fabric. WBEM EventID: 2947. WBEM ProviderName:
FPL_IndicationProvider.Warning10406
The cell/port pair does not exist in the Arches Fabric expected graph data. Data field:
CC port | (cellNum 32). Probable Cause: System firmware was unable to read a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
2948. WBEM ProviderName: FPL_IndicationProvider.Warning10407
A Cell-Cell link is connected to an unexpected neighbor port. Data field: expected
neighbor port | (actual neighbor port 32). Probable Cause: System firmware found
a discrepancy in the expected system topology. Recommended Action: Capture IPMI
event logs, look for additional errors. Contact your HP Support Representative to
analyze the fabric. WBEM EventID: 2949. WBEM ProviderName:
FPL_IndicationProvider.Warning10408
62 WBEM Provider Event Tables