The Arches Fabric vertex module returned an unexpected error during Non-Coherent
table setup. Data field: (return value) | (sourceCell 32) | (dest cell 48). Probable Cause:
Internal firmware error or data corruption. Recommended Action: Capture IPMI
event logs, look for additional errors. Contact your HP Support Representative to
analyze the fabric. WBEM EventID: 2959. WBEM ProviderName:
FPL_IndicationProvider.Warning10436
A write to a Skyline Global LINK_SEL_COHx CSR failed. Data field: cell number of
the Skyline that failed. Probable Cause: System firmware was unable to write a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
2960. WBEM ProviderName: FPL_IndicationProvider.Warning10439
Unable to write the XBC port scratch CSR with the routing state. Data field: (routing
state) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable
to write a fabric hardware register. Recommended Action: Capture IPMI event logs,
look for additional errors. Contact your HP Support Representative to analyze the
fabric. WBEM EventID: 2962. WBEM ProviderName: FPL_IndicationProvider.Warning10475
System Firmware was unable to access the configured set stored in the complex
profile. Probable Cause: SFW was unable to access the configured set stored in the
complex profile. Recommended Action: Collect IPMI events and contact your HP
Support Representative. WBEM EventID: 6874. WBEM ProviderName:
FPL_IndicationProvider.Warning10481
System Firmware detected an error during Fabric Init. Probable Cause: Error detected
by SFW during Fabric Init. Recommended Action: Collect IMPI events and contact
your HP Support Representative for assistance. WBEM EventID: 6869. WBEM
ProviderName: FPL_IndicationProvider.Warning10482
System Firmware detected a failure during Fabric Init. Probable Cause: Failure
detected by SFW during Fabric Init. Recommended Action: Collect IPMI events and
contact your HP Support Representative for assistance. WBEM EventID: 6870. WBEM
ProviderName: FPL_IndicationProvider.Warning10483
System Firmware detected an error during Fabric Optimize. Probable Cause: Error
detected by SFW during Fabric Optimize. Recommended Action: Collect IMPI events
and contact your HP Support Representative for assistance. WBEM EventID: 6871.
WBEM ProviderName: FPL_IndicationProvider.Warning10487
Input power to the specified UPS has failed. WBEM EventID: 2963. WBEM
ProviderName: FPL_IndicationProvider.Warning10489
Input power to the specified UPS has been restored. WBEM EventID: 2964. WBEM
ProviderName: FPL_IndicationProvider.Warning10490
UPS power exhausted. The system is being powered down. WBEM EventID: 2970.
WBEM ProviderName: FPL_IndicationProvider.Error10495
During Machine Check handling, SAL failed to rendezvous all the processors.
Probable Cause: System firmware cannot roundup the processors during the machine
check handler. Recommended Action: Check for faulty processor, possibly the one(s)
that failed to rendezvous. Contact your HP representative for support. WBEM
EventID: 6855. WBEM ProviderName: FPL_IndicationProvider.Warning10509
SAL failed to clear the CEC logs during Machine check handling. Probable Cause:
System firmware failed to clear the CEC logs. Recommended Action: Check for
multiple errors or bad CEC. Contact your HP representative for support. WBEM
EventID: 6856. WBEM ProviderName: FPL_IndicationProvider.Warning10510
SAL INIT failed to roundup the processors entering the SAL INIT handler. Probable
Cause: System firmware failed to roundup the processor during the INIT handler.
Recommended Action: Check for faulty processor, possibly the one(s) that failed to
rendezvous. Contact your HP representative for support. WBEM EventID: 8287.
WBEM ProviderName: FPL_IndicationProvider.Warning10513
System FW was unable to access the XBC semaphore. Probable Cause: System FW
was unable to access the XBC semaphore. Recommended Action: Collect IPMI events,
look for additional errors events, and contact HP support for assistance. WBEM
EventID: 6868. WBEM ProviderName: FPL_IndicationProvider.Warning10516