VM_DeleteVertex() failed in SynchGraphs(). Data field: (vertex id 32) | (vertex type
56) | (return value from VM_DeleteVertex()). Probable Cause: Internal firmware
error or data corruption. Recommended Action: Capture IPMI event logs, look for
additional errors. Contact your HP Support Representative to analyze the fabric.
WBEM EventID: 4525. WBEM ProviderName: FPL_IndicationProvider.Warning10619
VM_DeleteEdge() failed in the Arches Fabric function SynchGraphs(). Data
field:(vertex id1 32) | (vertex port1 48) | (vertex type1 56) | (vertex id2 0) | (vertex
port2 16) | (vertex type2 24). Probable Cause: Internal firmware error or data
corruption. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
4526. WBEM ProviderName: FPL_IndicationProvider.Warning10620
Unexpected error when calling an Arches Fabric vertex module function. Data field:
return value from vertex module function. Probable Cause: Internal firmware error
or data corruption. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
4527. WBEM ProviderName: FPL_IndicationProvider.Warning10621
Unexpected return from an Arches Fabric vertex module function while copying a
cell's graph. Data field: return value from vertex module function. Probable Cause:
Internal firmware error or data corruption. Recommended Action: Capture IPMI
event logs, look for additional errors. Contact your HP Support Representative to
analyze the fabric. WBEM EventID: 4528. WBEM ProviderName:
FPL_IndicationProvider.Warning10622
The checksum update for the PDT has failed. Probable Cause: The call to update the
checksum for the PDT failed. The PDT will most likely be cleared upon reboot.
Recommended Action: Reboot Upgrade SFW Contact HP support. WBEM EventID:
4529. WBEM ProviderName: FPL_IndicationProvider.Warning10623
The checksum in the memory area of NVM is bad. Probable Cause: The checksum
in the memory area of NVM is bad. Recommended Action: Upgrade SFW Contact
HP support. WBEM EventID: 4530. WBEM ProviderName: FPL_IndicationProvider.Warning10625
Checksum calculation failed. Probable Cause: The checksum calculation failed. The
data field contains the address that the checksum calculation was attempted on.
Recommended Action: Upgrade SFW Contact HP support. WBEM EventID: 4531.
WBEM ProviderName: FPL_IndicationProvider.Warning10626
Both SAL's copy and BMC copy of the token specified in the data field is bad. Probable
Cause: Both SAL's copy and BMC copy of the token specified in the data field is bad.
SFW is reinitializing that token to it's default value. Recommended Action: Verify
that the default settings are appropriate. For example, run the EFI baud and boot test
command. WBEM EventID: 4532. WBEM ProviderName: FPL_IndicationProvider.Warning10628
Incompatible I/O Backplane or I/O cables installed. Probable Cause: Incorrect I/O
backplane and/or I/O backplane cables are connected to the cell board. The cell board
is not compatible with I/O backplane and/or I/O backplane cables. Recommended
Action: Remove I/O backplane and/or I/O backplane cables and replace with
compatible I/O backplane and/or I/O backplane cables. WBEM EventID: 4533. WBEM
ProviderName: FPL_IndicationProvider.Error10629
The fPar identified by the event detail will be unusable. Probable Cause: Firmware
ran out of NVRAM before the server completed cold boot initialization. Recommended
Action: Initialize the NVRAM to the factory defaults and reset the server. Soft
partitions will have to be recreated from scratch before they are available. WBEM
EventID: 4667. WBEM ProviderName: FPL_IndicationProvider.Warning10698
Firmware is out of NVRAM and cannot built the ILM memory slice device map.
Probable Cause: Firmware ran out of NVRAM before the server completed cold boot
initialization. Recommended Action: Initialize the NVRAM to the factory defaults
and reset the server. Soft partitions will have to be recreated from scratch before they
are available. WBEM EventID: 4671. WBEM ProviderName: FPL_IndicationProvider.Error10702
The NVRAM for the CPU map is corrupt and cannot be trusted. It appears that there
are more CPUs in the map than the size of the map can hold. Probable Cause: This
should not show up and Firmware should have resolved this. WBEM EventID: 4672.
WBEM ProviderName: FPL_IndicationProvider.Error10703