HP Insight Management WBEM Provider Events Reference Guide

The NVRAM for the IO device ownership map is corrupt and cannot be trusted. It
appears that there are more IO devices in the map than the size of the map can hold.
Probable Cause: NVRAM corruption of fPars specific database. Recommended Action:
Restore NVRAM to factory defaults. Reset server and reconfigure soft partitions.
WBEM EventID: 4673. WBEM ProviderName: FPL_IndicationProvider.Error10704
The NVRAM for the cell local memory map is corrupt and cannot be trusted. It
appears that there are more memory slices in the map than the size of the map can
hold. Probable Cause: NVRAM corruption of fPars specific database. Recommended
Action: Restore NVRAM to factory defaults. Reset server and reconfigure soft
partitions. WBEM EventID: 4674. WBEM ProviderName: FPL_IndicationProvider.Error10705
An internal firmware inconsistency exists or the server exhausted its internal resources
and is unable to create an fPars EFI ownership variable for a CPU device in the
partition. Either of these conditions is fatal. Probable Cause: NVRAM corruption of
fPars specific database. Recommended Action: Restore NVRAM to factory defaults.
Reset server and reconfigure soft partitions. WBEM EventID: 4675. WBEM
ProviderName: FPL_IndicationProvider.Error10706
An internal firmware inconsistency exists or the server exhausted its internal resources
and is unable to create an fPars EFI ownership variable for an IO device in the
partition. Either of these conditions is fatal. Probable Cause: NVRAM corruption of
fPars specific database. Recommended Action: Restore NVRAM to factory defaults.
Reset server and reconfigure soft partitions. WBEM EventID: 4676. WBEM
ProviderName: FPL_IndicationProvider.Error10707
An internal firmware inconsistency exists or the server exhausted its internal resources
and is unable to create an fPars EFI ownership variable for a CLM device in the
partition. Either of these conditions is fatal. Probable Cause: NVRAM corruption of
fPars specific database. Recommended Action: Restore NVRAM to factory defaults.
Reset server and reconfigure soft partitions. WBEM EventID: 4677. WBEM
ProviderName: FPL_IndicationProvider.Error10708
Firmware has run out of NVRAM and cannot create the needed variable(s). Probable
Cause: NVRAM is too full for operation. Recommended Action: Delete some EFI
variables in existing fPars or boot in nPars mode and delete some variables. (E.g.,
too many boot paths in the boot manager can cause this). Clear NVRAM and
reconfigure system. WBEM EventID: 4756. WBEM ProviderName:
FPL_IndicationProvider.Warning10771
The call to the IOC firmware component method 'LbaReconfig' failed, probably a
low-level hardware error. The fPar BSP is identified in bits 63..32 of the event detail,
the fPar owning this CPU and LBA is identified in bits 31..16. Probable Cause: Low
level IO hw initialization of an LBA by the firmware failed during an fPar reset.
Recommended Action: Try booting nPars mode. Power cycle the hardware. replace
the LBA. WBEM EventID: 4757. WBEM ProviderName: FPL_IndicationProvider.Warning10772
Invocation of the soft reset code from an interrupt or similar vector,. Probable Cause:
An error in the system firmware. Recommended Action: Reset the nPar. WBEM
EventID: 4696. WBEM ProviderName: FPL_IndicationProvider.Error10793
Data field is count of cpus held by the sm4 which issues the event (and is trying to
reset itself). Indicates invocation of the SoftResetCpu code from an interrupt or similar
vector. Probable Cause: An error in the system firmware. Recommended Action:
Reset the nPar. WBEM EventID: 4697. WBEM ProviderName: FPL_IndicationProvider.Error10794
A reset of an fPar discovered that an fPar failed to release critical resources within a
reasonable time. Probable Cause: Fpar reset to an Fpar which failed to release critical
resources within a reasonable time. Recommended Action: No action is required.
The nPar will be rebooted. WBEM EventID: 4698. WBEM ProviderName:
FPL_IndicationProvider.Error10795
Significant numbers of corrected memory errors have been detected on the memory
subsystem. Probable Cause: You will receive this message if the system is observing
a lot of corrected ECC errors in memory. This could be caused by problems with the
system's memory or by unexpected environmental conditions inside the server.
Recommended Action: Contact your HP support representative to check your memory
system. WBEM EventID: 4542. WBEM ProviderName: FPL_IndicationProvider.Warning10814
68 WBEM Provider Event Tables