HP Insight Management WBEM Provider Events Reference Guide

Over-temperature condition detected on a processor. Probable Cause: The processor
temperature is above the operating range. The processor's performance is throttled
by the firmware to reduce the temperature. Recommended Action: The firmware
has already taken necessary action. Once the temperature comes down, the firmware
will restore the processor's performance to normal. WBEM EventID: 4543. WBEM
ProviderName: FPL_IndicationProvider.Warning10822
Cache errors detected on a processor. Probable Cause: Threshold parity errors have
been detected in the Instruction or Data Cache Memory (I-Cache or D-Cache). The
operating system has recovered from the errors, but this is an abnormally high failure
rate. Recommended Action: Contact your HP support representative to check the
processor. WBEM EventID: 4544. WBEM ProviderName: FPL_IndicationProvider.Warning10823
Corrected errors detected in the cache portion of the memory for a processor module.
Probable Cause: Threshold corrected platform errors have been detected in the cache
portion of the memory for the processor module. The operating system has recovered
from the errors, but this is an abnormally high failure rate. Recommended Action:
Contact your HP support representative to check the processor. WBEM EventID:
4545. WBEM ProviderName: FPL_IndicationProvider.Warning10824
Corrected errors detected on the system bus for a processor module. Probable Cause:
Threshold corrected platform errors have been detected on the system bus for the
processor module. The operating system has recovered from the errors, but this is
an abnormally high failure rate. Recommended Action: Contact your HP support
representative to check the processor module or the system bus for the processor if
an excessive number of these errors are generated. WBEM EventID: 4546. WBEM
ProviderName: FPL_IndicationProvider.Warning10825
Corrected errors detected on the processor bus for a processor module. Probable
Cause: Threshold corrected platform errors have been detected on the processor bus
for the processor module. The operating system has recovered from the errors, but
this is an abnormally high failure rate. Recommended Action: Contact your HP
support representative to check the processor module or the system bus for the
processor if an excessive number of these errors are generated. WBEM EventID: 4547.
WBEM ProviderName: FPL_IndicationProvider.Warning10826
Corrected errors detected in the tag portion of the memory for a processor module.
Probable Cause: Threshold corrected platform errors have been detected in the tag
portion of the memory for the processor module. The operating system has recovered
from the errors, but this is an abnormally high failure rate. Recommended Action:
Contact your HP support representative to check the processor module if an excessive
number of these errors are generated. WBEM EventID: 4548. WBEM ProviderName:
FPL_IndicationProvider.Warning10827
fPars-mode EFI variable is set to enable fPars operation but no fPars are actually
enabled to boot. So the server boots in hard partition mode. Probable Cause:
fPars-mode EFI variable is set to enable fPars operation but no fPars are actually
enabled to boot. So the server boots in hard partition mode. This is a configuration
usage problem, possibly a user error such as might occur if a previously bootable
config was made unbootable by setting the enabled fPar existence variables, e.g.,
'fPar0', 'fPar1', ... 'fParN' to 0x00 (disabled) and then rebooting. Recommended Action:
Use the configuration tool released with the OS to disable fPars mode or to configure
and enable bootable fPars. WBEM EventID: 4700. WBEM ProviderName:
FPL_IndicationProvider.Warning10830
An fPar was directed to reset using the ESIT DirectedfParResetAndMigrate() service
but the target (recipient) fPar of the resources is in a state that cannot receive
ownership of these resources. Probable Cause: An fPar was directed to reset using
the ESIT DirectedfParResetAndMigrate() service but the target (recipient) fPar of the
resources is in a state that cannot receive ownership of these resources. Recommended
Action: Use the configuration tool released with the OS to correctly assign these
resources to an fPar and reset that fPar so they will be claimed. WBEM EventID: 4701.
WBEM ProviderName: FPL_IndicationProvider.Warning10832
Platform Events 69