HP Insight Management WBEM Provider Events Reference Guide

The operational clock frequencies do not match between the Redundant Clock Source
(RCS) and the Hot Swap Oscillator (HSO). The data field contains the physical location
of the HSO. Probable Cause: Operating frequency of the HSO does not match that
of the RCS. Recommended Action: Check HSO assembly. WBEM EventID: 4916.
WBEM ProviderName: FPL_IndicationProvider.Warning11478
The clock margin of the system backplane failed. WBEM EventID: 4917. WBEM
ProviderName: FPL_IndicationProvider.Error11479
System backplane Hot Swap Oscillator (HSO) boards are NOT redundant. Probable
Cause: HSO assembly has been removed or has a fault condition. Recommended
Action: look for additional events describing action to take. WBEM EventID: 5231.
WBEM ProviderName: FPL_IndicationProvider.Warning11481
System backplane Hot Swap Oscillator (HSO) boards are insufficient. Probable Cause:
There are no HSO present or all clock sources have faulted. Recommended Action:
Look for additional events describing action to take. WBEM EventID: 4918. WBEM
ProviderName: FPL_IndicationProvider.Error11482
Failure reading Redundant Clock Source (RCS) or Hot Swap Oscillator HSO boards
EEPROM. Probable Cause: device is not accessible over i2c. Recommended Action:
check HSO + RCS boards. WBEM EventID: 4919. WBEM ProviderName:
FPL_IndicationProvider.Warning11483
Failure writing Redundant Clock Source (RCS) or Hot Swap Oscillator HSO boards
EEPROM. Probable Cause: device is not accessible over i2c. Recommended Action:
check HSO and RCS boards. WBEM EventID: 4920. WBEM ProviderName:
FPL_IndicationProvider.Error11484
Failure reading the Reset and Power Monitors (RPM) EEPROM. Probable Cause:
device is not accessible over i2c. Recommended Action: check backplane power.
WBEM EventID: 4921. WBEM ProviderName: FPL_IndicationProvider.Error11485
Failure writing the Reset and Power Monitors (RPM) EEPROM. Probable Cause:
device is not accessible over i2c. Recommended Action: check backplane power.
WBEM EventID: 4922. WBEM ProviderName: FPL_IndicationProvider.Error11486
Failure reading the Onboard System Programmers (OSP) EEPROM. Probable Cause:
device is not accessible over i2c. Recommended Action: check backplane power.
WBEM EventID: 4923. WBEM ProviderName: FPL_IndicationProvider.Error11487
Failure writing the Onboard System Programmers (OSP) EEPROM. Probable Cause:
device is not accessible over i2c. Recommended Action: check backplane power.
WBEM EventID: 4924. WBEM ProviderName: FPL_IndicationProvider.Error11488
SBS fault on startup. Probable Cause: SBS block for one of the MOAB's has reported
an error on startup. Recommended Action: check backplane power. The physical
location of the MOAB reporting the error is provided by data field.
0xFFFFXXFFFFFFFFFF where XX is: XX = 0x00 - Moab 0x00 XX = 0x01 - Moab 0x01
XX = 0x02 - Moab 0x02 XX = 0x10 - Moab 0x40 XX = 0x11 - Moab 0x41 XX = 0x12 -
Moab 0x42. WBEM EventID: 4925. WBEM ProviderName: FPL_IndicationProvider.Error11489
Failure reading IO backplane LPM. Probable Cause: IO backplane LPM is not
accessible over i2c. Recommended Action: Check power status of IO backplane.
WBEM EventID: 4926. WBEM ProviderName: FPL_IndicationProvider.Warning11495
Failure writing IO backplane LPM. Probable Cause: IO Backplane LPM is not
accessible over i2c. Recommended Action: Check power status of IO backplane.
WBEM EventID: 4927. WBEM ProviderName: FPL_IndicationProvider.Warning11496
The system software violated one of the 'well-behavedness' rules of soft partitions
and tried to call a firmware procedure within the firmware instance of a sibling. This
is an access violation and firmware rejects the call. Probable Cause: System Software
Defect - using the wrong entry address for the owner of the CPU. Recommended
Action: Update the system software. WBEM EventID: 4928. WBEM ProviderName:
FPL_IndicationProvider.Warning11515
Platform Events 73