HP Insight Management WBEM Provider Events Reference Guide

AlbInitPrep was unable to read the ALREC_CONFIG CSR to determine whether the
link is up or not. Data field: unused. Probable Cause: An error occurred while routing
the fabric. Recommended Action: Collect IPMI event logs, and contact your HP
support representative to inspect the fabric and system firmware. WBEM EventID:
4929. WBEM ProviderName: FPL_IndicationProvider.Warning11521
The fPar whose ID is identified in the event detail is disabled from booting because
it has no bootable, healthy CPU. It may not own any CPU or the CPUs it owns are
Unhealthy (or deconfigured). Probable Cause: The fPar whose ID is identified in the
event detail is disabled from booting because it has no bootable, healthy CPU. It may
not own any CPU or the CPUs it owns are Unhealthy (or deconfigured).
Recommended Action: Use the soft partitioning configuration tool released with the
OS product to reconfigure the fPar and reboot the partition. A cold reset of the hard
partition may be required. WBEM EventID: 4930. WBEM ProviderName:
FPL_IndicationProvider.Warning11529
Non-critical event announces that an fPar is enabled to boot but has inadequate
memory resources to instantiate the firmware for the fPar. The configuration is
modified to disable but not delete this fPar. Probable Cause: The user has configured
an fPar to be booted with inadequate memory resources to instantiate the firmware
image for this fPar. The fPar is software deconfigured (disabled) from booting.
Recommended Action: Reconfigure the fPar, giving it at least instance-size (an fPars
EFI variable) amount of physically contiguous RAM. Then re-enable and reset the
fPar. WBEM EventID: 4931. WBEM ProviderName: FPL_IndicationProvider.Warning11530
The fPar has been enabled to boot, and contains at least one CPU and adequate
memory but has not been given any IO resources. It must be reconfigured and reset
before it may boot an operating system. Probable Cause: The fPar has been enabled
to boot, and contains at least one CPU and adequate memory but has not been given
any IO resources. The soft partition (fPar) may therefore only boot as far as the EFI
shell. It must be reconfigured and reset before it may boot an operating system.
Recommended Action: Reconfigure the soft partition using an
Operating-system-specific utility then reset the soft partition. WBEM EventID: 4932.
WBEM ProviderName: FPL_IndicationProvider.Warning11531
All processors are scheduled for deconfiguration. Probable Cause: All CPUs were
scheduled to be deconfigured through a combination of user deconfigures and/or
failures. Recommended Action: No action is required. WBEM EventID: 5270. WBEM
ProviderName: FPL_IndicationProvider.Warning11537
Processors have been reconfigured due to installation of a new processor type, or
SFW revision change. Probable Cause: Either all CPUs were slated for deconfiguration,
or NVM has been cleared, or a new CPU type has been installed. Recommended
Action: No action is required. WBEM EventID: 5262. WBEM ProviderName:
FPL_IndicationProvider.Warning11538
IO Backplane 1.5V power fault. Probable Cause: One of the 1.5v VRM's is reporting
a fault, one failure and power state is N, after two power state will be N-.
Recommended Action: Check IO backplane power board faulted VRM is give by PS
command. WBEM EventID: 7663. WBEM ProviderName: FPL_IndicationProvider.Error11565
IO Backplane 3.3V power fault. Probable Cause: One of the 3.3v VRM's is reporting
a fault, one failure and power state is N, after two power state will be N-.
Recommended Action: Check IO backplane power board faulted VRM is give by PS
command. WBEM EventID: 6825. WBEM ProviderName: FPL_IndicationProvider.Error11566
IO Backplane 5.0V power fault. Probable Cause: One of the 5.0v VRM's is reporting
a fault, one failure and power state is N, after two power state will be N-.
Recommended Action: check IO backplane power board faulted VRM is give by PS
command. WBEM EventID: 6826. WBEM ProviderName: FPL_IndicationProvider.Error11567
IO Backplane -12V power fault. Probable Cause: One of the -12v VRM's is reporting
a fault, one failure and power state is N, after two power state will be N-.
Recommended Action: Check IO backplane power board faulted VRM is give by PS
command. WBEM EventID: 6827. WBEM ProviderName: FPL_IndicationProvider.Error11568
74 WBEM Provider Event Tables