HP Insight Management WBEM Provider Events Reference Guide

Unable to route around broken link. Probable Cause: A traversable route between
the local cell and the specified destination crossbar could not be found. Recommended
Action: Capture IPMI event logs. Contact your HP Support Representative to
investigate the fabric subsystem. WBEM EventID: 5187. WBEM ProviderName:
FPL_IndicationProvider.Warning12008
Unable to set the APER 'fabric lockdown' bit. Probable Cause: Internal FW error.
Recommended Action: Reset partition. WBEM EventID: 5188. WBEM ProviderName:
FPL_IndicationProvider.Warning12013
An uncorrectable memory ECC error has occurred. The data field gives the physical
location of the DIMM that had the error. Probable Cause: An uncorrectable memory
ECC error has occurred. Recommended Action: Replace all DIMMs in the memory
rank specified in the physical location info. If problem persists, contact HP support
to troubleshoot the problem. WBEM EventID: 6860. WBEM ProviderName:
FPL_IndicationProvider.Error12017
An error encountered while retrieving the expected neighbor fabric chip for
distributing traffic over crossbar links. Probable Cause: Unexpected error retrieving
information from the fabric graph. Recommended Action: Collect IPMI event logs
and contact your HP Support Representative to investigate the fabric system firmware
subsystem. WBEM EventID: 5189. WBEM ProviderName: FPL_IndicationProvider.Warning12025
Could not read crossbar neighbor information during routing. Probable Cause: System
Firmware encountered an error while reading a fabric crossbar chip. Recommended
Action: Collect IPMI Event Logs and contact your HP Service Representative to
investigate the fabric subsystem. WBEM EventID: 5190. WBEM ProviderName:
FPL_IndicationProvider.Warning12028
Could not establish route for local crossbar during route around routing. Probable
Cause: System Firmware could not establish routing from the local crossbar that
would be needed to complete the route around routing. Recommended Action:
Collect IPMI Event Logs and contact your HP Support Representative to investigate
the fabric subsystem. WBEM EventID: 5191. WBEM ProviderName:
FPL_IndicationProvider.Warning12029
An invalid or non-supported TPM (Trusted Platform Module) has been detected.
Ensure that the TPM is fully seated into the system board and verify the operating
system is TPM capable. Probable Cause: An invalid, non supported TPM is being
used in the system. Recommended Action: Contact HP for support. WBEM EventID:
5193. WBEM ProviderName: FPL_IndicationProvider.Error12047
Invalid or unsupported TPM detected in the system. TPM is disabled. Probable Cause:
An invalid or unsupported TPM has been detected in the system. TPM is disabled.
Recommended Action: Contact HP support. WBEM EventID: 5194. WBEM
ProviderName: FPL_IndicationProvider.Warning12048
TPM failed initialization. Security features disabled. Probable Cause: Bad TPM chip.
Recommended Action: contact HP support. WBEM EventID: 5195. WBEM
ProviderName: FPL_IndicationProvider.Warning12049
A CPU module's temperature has exceed the high temperature threshold or a CPU
power module fault has occurred. As a result of this event, the CPU has been inhibited.
The Cell must be powered off then on using the MP's PE command to clear. Probable
Cause: A CPU module's temperature has exceed the high temperature threshold or
a CPU power module fault has occurred. Recommended Action: Contact HP support
personnel to troubleshoot the problem. WBEM EventID: 5192. WBEM ProviderName:
FPL_IndicationProvider.Error12050
SFW detected an error while writing to stable store flash. Probable Cause: Cosmic
radiation Bad flash part. Recommended Action: Reboot, if problem persists, contact
HP support. WBEM EventID: 6861. WBEM ProviderName: FPL_IndicationProvider.Warning12069
Stable Store data is uninitialized or invalid. Probable Cause: Bad checksum on the
stable store area. Cosmic radiation Bad flash part. Recommended Action: Reboot, if
problem persists, contact HP support. WBEM EventID: 8288. WBEM ProviderName:
FPL_IndicationProvider.Warning12070